beautypg.com

JLG 110HX Operator Manual User Manual

Page 67

background image

SECTION 4 - MACHINE OPERATION

3120889

– JLG Lift –

4-9

4.9

BOOM

A RED TILT ALARM WARNING LIGHT, LOCATED ON THE CON-
TROL CONSOLE, LIGHTS WHEN THE CHASSIS IS ON A SEVERE
SLOPE (3 DEGREES OR GREATER). DO NOT SWING, EXTEND OR
RAISE BOOM ABOVE HORIZONTAL WHEN LIT.

DO NOT DEPEND ON TILT ALARM AS A LEVEL INDICATOR FOR
THE CHASSIS. TILT ALARM INDICATES CHASSIS IS ON A
SEVERE SLOPE (3 DEGREES OR GREATER). CHASSIS MUST BE
LEVEL BEFORE SWINGING, EXTENDING OR RAISING BOOM
ABOVE HORIZONTAL.

TO AVOID UPSET, IF RED TILT ALARM WARNING LIGHT LIGHTS
WHEN MAIN BOOM IS EXTENDED OR RAISED ABOVE HORIZON-
TAL, RETRACT AND LOWER PLATFORM TO NEAR GROUND
LEVEL. THEN REPOSITION MACHINE SO THAT CHASSIS IS
LEVEL BEFORE EXTENDING OR RAISING BOOM.

TRAVELING WITH BOOM RETRACTED AND BELOW HORIZONTAL
IS PERMITTED ON GRADES AND SIDE SLOPES SPECIFIED ON
CAUTION PLACARD AT PLATFORM.

TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINERY IF
ANY CONTROL LEVERS OR TOGGLE SWITCHES CONTROLLING
PLATFORM MOVEMENT DO NOT RETURN TO THE OFF OR NEU-
TRAL POSITION WHEN RELEASED.

TO AVOID A COLLISION AND INJURY IF PLATFORM DOES NOT
STOP WHEN A CONTROL SWITCH OR LEVER IS RELEASED,
REMOVE FOOT FROM FOOTSWITCH OR USE EMERGENCY STOP
TO STOP THE MACHINE.

Swinging the Boom

ASSURE THAT TURNTABLE LOCK IS DISENGAGED BEFORE
STARTING ANY SWING OPERATION.

1.

Depress footswitch to swing boom, position SWING
control switch or controller to RIGHT or LEFT for
direction desired.

NOTE: When boom functions are being operated there is an

interlock that prevents the use of DRIVE and STEER
functions.

Raising and Lowering the Main Boom

To raise and lower Boom, position LIFT control switch or
controller to UP OR DOWN and hold until desired height is
reached.

Telescoping the Main Boom

To extend or retract Boom, position TELESCOPE control
switch to IN or OUT and hold until platform reaches
desired position.

4.10 SHUT DOWN AND PARK

1.

Drive machine to a protected area.

2.

Position HIGH ENGINE speed control switch on
Platform Control Console to LOW.

3.

Assure main boom is fully retracted and lowered
over rear (Drive) axle; all access panels and doors
closed and secured.

4.

Remove all load and allow engine to operate 3-5
minutes at LOW setting to permit reduction of
engine internal temperatures.

5.

At Ground Controls, turn MASTER SWITCH to (cen-
ter) OFF. Position, the IGNITION switch (down) to
OFF.

6.

Cover the Platform Control Console to protect
instruction placards, warning decals and operating
controls from hostile environment.

This manual is related to the following products: