Userguide no – Eppendorf Piezo-actuated Mouse ICSI (intracytoplasmic sperm injection) User Manual
Page 8

Userguide No
Your local distributor: www.eppendorf.com/worldwide
Eppendorf AG · 22331 Hamburg · Germany · Tel: +49 40 53801-0 · Fax: +49 40 538 01-556 · E-mail: [email protected]
Eppendorf North America, Inc. · 102 Motor Parkway · Hauppauge, N.Y. 11788-5178 · USA
Tel: +1 516 334 7500 · Toll free phone: +1 800-645-3050 · Fax: +1 516 334 7506 · E-mail: [email protected]
Application Support Europe, International: Tel: +49 1803 666 789 (Preis je nach Tarif im Ausland;
9 ct/min aus dem dt. Festnetz; Mobilfunkhöchstpreis 42 ct/min) · E-mail: [email protected]
North America: Tel: +1 800 645 3050 · E-mail: [email protected]
Asia Pacific: Tel: +60 3 8023 6869 · E-mail: [email protected]
037
Galaxy
®
is a r
egis
ter
ed tr
ademar
k of Ne
w Br
unswic
k, Eppendor
f A
G • Fluoriner
t™
is a T
rademar
k fr
om 3M Com
pan
y U
nit
ed S
tat
es of America , Maple
w
ood, Minneso
ta
eppendor
f
®
, Eppendor
f PiezoXper
t
®
,
T
ransf
erMan
®
and CellT
ram
®
ar
e r
egis
ter
ed tr
ademar
ks of Eppendor
f A
G • Piezo DrillT
ip Mouse ICSI
™
, Piezo Drill T
ip ES
™
, Micr
oloader
™,
P
atc
hMan
™
and V
acuT
ip
™
ar
e tr
ademar
ks of Eppendor
f A
G
Or
der
-No. A
U0 37WW 020/GB2/0T/0812/CREA • All r
ights r
eser
ved, including g
raphics and images • Cop
yr
ight © 2011 - 2012 b
y Eppendor
f A
G
Ordering information
Product
Description
Order no.
International
Order no.
North America
Eppendorf PiezoXpert®
Basic device incl. Actuator, Foot control and spacer plate*
5194 000.016
5194000024
TransferMan® NK 2 **
Proportional micromanipulator for suspension cells
5188 000.012
920000011
CellTram® Air **
Manual pressure device for the reliable holding of suspended
cells
5176 000.017
920002021
CellTram® Oil **
Manual pressure device for the reliable holding of suspended
cells
5176 000.025
920002030
CellTram® vario **
Manual hydraulic microinjector, with gears 1:1 and 1:10
5176 000.033
920002111
VacuTip™ ** and ***
25 glass capillaries for holding large cells (e.g. eggs), sterilized,
tip angle 35°
5175 108.000
930001015
PiezoDrill
Tip Mouse ICSI™
25 glass capillaries for the transfer of mouse sperms, angle 25° 5175 220.005
930001091
PiezoDrill
Tip ES™
25 glass capillaries for the transfer of embryonal stem cells,
angle 25°
5175 250.001
930001104
Microloader™
Capillary tips for filling microinjection capillaries, set of 2x 96
pcs.
5242 956.003
930001007
Microscope Adapter
Adapter for micromanipulators available for different inverse
microscopes
Available on
request
Available on
request
GALAXY® 14 S (230 V) **** Incubator
CO14S-230-0000
GALAXY® 14 S (230 V) **** Incubator with 1-19 % O
2
control
CO14S-2300200
GALAXY® 14 S (120 V) **** Incubator
CO14S-120-0000
GALAXY® 14 S (120 V) **** Incubator with 1-19 % O
2
control
CO14S-120-0200
*
For mounting the PiezoXpert onto TransferMan NK 2 or PatchMan NP 2
** This product is registered in Europe as a medical device (according to Medical Device Directive MDD/93/42/EDD). This
product is not registered in the U.S. as a medical device and does not have a 510(k) registration. For resarch use only.
Not for use in human medical applications.
*** Proven non cytotoxicity by the mouse embryo development test.
**** New Brunswick CO
2
Incubators have been designed for research use only. New Brunswick CO
2
Incubators in general
are not certified for any human IVF/medical application