TROUBLESHOOTING (cont.)
Problem

Beverage level will not adjust
(Selector switch in any position)

Water flows into tank continuously
.

Water flows into tank continuously
(ON/OFF switch "ON").

Water from tank is not hot

Probable Cause

1. Brew Selector switch

1. Solenoid valve

2A. Level control board and level
probe (Electro/mechanical)

2B. Control assembly (Electronic)

1. Timer

2. Overflow protection switch

1. Limit thermostat

CAUTION - Do not eliminate or by-
pass limit thermostat. Use only re-
placement part #23717.0001

2A. Control Thermostat (Electro/me-
chanical)

2B. Control assembly (Electronic)

3. Contactor (Brewers with Recov-
ery Booster)

4. Tank heaters

5. Triac assembly (Electronic)

Remedy

Refer to

Service

- Selector switch for

testing procedures. See page 15

Refer to

Service

- Solenoid valve for

testing procedures. See page 35

Refer to

Service

- Level control board

for test procedures. See page 28

Refer to

Service

- Control assembly

for testing procedures. See page 22
thru 27

Refer to

Service

- Timer for testing

procedures. See page 38 or 41

Refer to

Service

- Overflow protec-

tion switch for testing procedures.
See page 32

Refer to

Service

-Limit thermostat

for testing procedures. See page 30

Refer to

Service

- Control Thermo-

stat for testing procedures. See page
19

Refer to

Service

- Control assembly

for testing procedure. See page 22
thru 27

Refer to

Service

- Contactor for test-

ing procedures. See page 17

Refer to

Service

- Tank heaters for

testing procedures. See page 37

Refer to

Service

- Triac assembly for

testing procedures. See page 26

27040 032201