Bryston MPS2 User Manual
Page 6
MPS2_MANUAL_20060324
REPLACING FUSES IN THE MPS2 POWER SUPPLY
CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of
electric shock do not perform any servicing other than that contained in the operating instructions unless you
are qualified to do so.
All fuses are 5mm x 20mm, time lag type and are accessible only by removing the top cover. When
replacing fuses, disconnect the power cord before opening the unit!
Recommended replacement fuses:
100V~ models: T 2.5A L 250v Littlefuse 218 02.5
110V~ models: T 2.0A L 250v Littlefuse 218 002
120V~ models: T 2.0A L 250V Littlefuse 218 002
200V~ models: T 1.25A L 250v Littlefuse 218 1.25
220V~ models: T 1A L 250v
Littlefuse 218 001
230V~ models: T 1A L 250v
Littlefuse 218 001
240V~ models: T 1A L 250v
Littlefuse 218 001