Cf panel, Recommended screw placement table, Fastening schedule spacing along panel nail strip – Mueller CF Panel User Manual
Page 12

RECOMMENDED SCREW PLACEMENT TABLE
Details are subject to change without prior notice.
Note: If using treated lumber, special corrosive resistant screws are required. Ask your sales representative for more information.
Zone
FASTENER
SUBSTRATE
90
ON CENTER
SPACING
100
ON CENTER
SPACING
110
ON CENTER
SPACING
120
ON CENTER
SPACING
130
ON CENTER
SPACING
140
ON CENTER
SPACING
Zone 1
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
20”
20”
15”
Type 1, 20”
20”
20”
15”
Type 1, 20”
20”
20”
15”
Type 1, 20”
20”
20”
15”
Type 1, 20”
20”
20”
N/A
Type 1, 20”
N/A
N/A
N/A
Type 1, 10”
Zone 2
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
20”
20”
15”
Type 1, 20”
20”
20”
15”
Type 1, 20”
10”
20”
15”
Type 2, 20”
10”
10”
10”
Type 2, 10”
10”
10”
N/A
Type 2, 10”
N/A
N/A
N/A
Type 2, 10”
Zone 3
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
10”
20”
15”
Type 2, 10”
10”
10”
10”
Type 2, 10”
10”
10”
10”
Type 2, 10”
10”
10”
10”
Type 2, 10”
10”
10”
N/A
Type 2, 10”
N/A
N/A
N/A
Type 2, 10”
Zone
FASTENER
SUBSTRATE
90
ON CENTER
SPACING
100
ON CENTER
SPACING
110
ON CENTER
SPACING
120
ON CENTER
SPACING
130
ON CENTER
SPACING
140
ON CENTER
SPACING
Zone 1
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
10”
25”
15”
Type 2, 10”
Zone 2
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
10”
25”
15”
Type 2, 10”
10”
25”
10”
Type 2, 10”
Zone 3
#10-12 X 1”
15/32” CDX
19/32” CDX
7/16” OSB
1x4 Wood Purlins
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
20”
25”
15”
Type 1, 20”
10”
25”
15”
Type 2, 10”
10”
25”
10”
Type 2, 10”
WIND SPEED ZONE
FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP
With < 30’-0” mean roof height -
3:12 to 6:12 pitch
for 90-140 mph wind speeds based on ASCE 7-93
WIND SPEED ZONE
FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP
With < 30’-0” mean roof height -
7:12 to 12:12 pitch
for 90-140 mph wind speeds based on ASCE 7-93
CF PANEL