C - user presets for the sk450, U2 - lock or unlock door, U3 - move clamp plate – Fast & Fluid SK450 User Manual
Page 15: U4 - standby interval
p15
Fast & Fluid Management - SK450
C - User presets for the SK450
Certain SK450 software presets can be adjusted using the interface screen and buttons. To enter the User
Mode menu, press the emergency stop button and then unlock it while simultaneously keeping the program
button (P) pressed.
Upon entering the User
Mode menu, a screen will
appear showing your
SK450 ’s life in mixing
cycles and total hours.
Press the program button
to run through the different
user menu’s.
U2 - Lock or unlock door
The U2 option is used to
either lock or unlock the
door manually. This may be
necessary after a power
failure or accidentally
closing the door while the
power is down.
U3 - Move clamp plate
The U3 option is used to
force the clamp plate to
move either up or
downwards. This may be
necessary in case of the
clamp plate jamming in its
upper or lower position.
U4 - Standby interval
The U4 option is used to define
the amount of time before
entering standby modus.