It is important to clean the heater on a regular basis to

maintain proper combustion and to eliminate future

problems.

The frequency of cleaning will vary depending upon

livestock being raised and overall ventilation of the building.

Problems associated with lack of cleaning typically are:

Black soot on inside of canopy.

Gas backflashing in venturi tube or injector body.

Burner flame appearing beyond outer cone.

AA.. HHEEAATTEERR

CLEANING WITH BACKPACK BLOWERS

AND HEATER BLOWER

Blower Part No. 21170

For general cleaning when the heaters do not have heavy

accumulations of dust or dirt, use either a backpack type of

blower or the heater blower.

Follow the same procedures for cleaning as listed for

Cleaning with Compressed Air.

If the dust and dirt cannot be removed effectively using the

backpack blower or heater blower, then clean the heater

using either the Compressed Air or Water Cleaning methods.

CLEANING WITH COMPRESSED AIR

1. Turn off the gas supply to the heater and let the

heater cool.

2. Direct the air at the combustion cones, working your

way around entire surface of cone assembly.

3. Blow air through air inlet opening in the venturi tube

to blow back out any loosened dust through

combustion cones.

4. Repeat Steps 2 and 3 until the cones and the venturi

tube are no longer emitting dust.

5. Inspect the cones and venturi tube to make sure

these areas are clean.

6. Return the heater to its normal hanging position and

relight the heater.

FIG. 9

CLEANING WITH WATER

(Continued on page 13)

TThhee ffoolllloowwiinngg sshhoouulldd bbee aaccccoom

mpplliisshheedd oonnllyy iiff tthhee hheeaatteerr

ccaannnnoott bbee cclleeaanneedd aaddeeqquuaatteellyy bbyy tthhee ccoom

mpprreesssseedd aaiirr

m

meetthhoodd.. DDOO NNOOTT UUSSEE HHIIGGHH PPRREESSSSUURREE W

WAASSHHEERRSS!!

1. Wrap the pressure switch and safety control valve

with a plastic bag to protect these components from

entry of water.

2. Using a standard garden hose with standard faucet

pressure, spray water against the cones to wash out

the build up of dust in the cones and the venturi tube.

Work your way around the entire cone assembly.

See Fig. 10.

FIG. 10

3. Position the heater as shown in Fig. 11 and run water

down through the venturi tube and out through

combustion cones.

AIR NOZZLE

1122

LEAD END OF THERMOCOUPLE

THERMOFUSE

5/16"

COVER

UPPER NUT

THERMOCOUPLE
LEAD

COVER

LOWER NUT

Cleaning Instructions

WATER HOSE

CCAAUUTTIIOONN

Disinfectants utilized in agricultural animal

confinement buildings may contain chemicals

damaging to components of the heater.

Protect the safety gas control valve and pressure

valve by wrapping these components with a plastic

bag before disinfecting.

Always make sure to remove the plastic bag or other

protective covering before start up.