Burner orifice motor and fan assembly – L.B. White Sentinel Radiant Tube AT150 40' Center Mount User Manual
Page 20
1. Remove the igniter
2. Remove the clear flexible tube from the pressure
switch. Fig.22.
3. Remove the four nuts from the burner mounting studs
and remove burner . See Fig.22.
FIG. 22
4.
Securely hold the burner manifold in place while
removing the orifice from the manifold. See Fig. 23.
Inspect the orifice and clean out any dirt. Replace it if
necessary.
FIG. 23
5.
When reinstalling the burner, ensure larger opening
between burner vanes is directed to the access door
of the burner box. See Fig.24
FIG. 24
BURNER ORIFICE
MOTOR AND FAN ASSEMBLY
19
NUTS
TUBE
LARGER OPENING
1.
Remove all fan housing mounting nuts. See Fig. 25.
2.
Tilt the motor and fan assembly slightly and pull
upward.
FIG. 25
3.
Remove inlet side of housing. See Fig. 26. Loosen
set screw on fan hub with a TORX 20 driver.
4.
Pull fan wheel from housing. Remove nuts holding
housing to motor mounting studs.
FIG. 26
ORIFICE
MANIFOLD
NUTS
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)