Shut-down instructions, Cleaning instructions, Start-up instructions – L.B. White 200 Norseman User Manual
Page 10

IGNITER BUTTON
PILOT BUTTON
9
1. Close manual main burner valve on heater.
2. Slowly open the propane gas supply container valve.
3. Fully depress the button on the pilot safety control
valve while pushing the igniter button.
4. Keep the pilot button depressed for about 30
seconds to allow the thermocouple to warm up.
5. Open the manual main burner valve located between
the pilot safety control and burner.
FIG. 3
ATTENTION
■
On new installations it will take a short time for gas to
purge out any air in the pilot line and hose before the
pilot may be lit.
A. To properly shut heater down after normal use, or
when further use is anticipated:
-- Close manual main burner valve on heater.
B. To properly shut heater down for storage, or when
further use is not anticipated:
1. Close propane gas supply container valve. Allow
heater to burn off remaining gas in its hose.
2. Close manual main burner valve on heater.
3. Disconnect the heater from its gas supply.
Shut-Down Instructions
WARNING
Fire oor EExplosion H
Hazard
■
Use only your hand to depress the gas control button.
Never use any tools.
■
If the button will not depress by normal hand pressure,
the control should be replaced by a qualified service
person.
■
Force or attempted repair may result in a fire or
explosion causing property damage, severe injury, or
death.
1. Before cleaning, close all gas supply valves.
2. The heater should have dir t or dust removed
periodically:
a. Before each use give the heater a general
cleaning using compressed air, a soft brush, or
dry rag, on its case and internal components.
b. At least once a year, give the heater a thorough
cleaning. At this time, remove the burner
assembly and brush and/or blow off the burner
and related components.
WARNING
Do not use a pressure washer, water, or liquid cleaning
solution on any gas controls. Use of a pressure washer,
water, or liquid cleaning solution on the control
components can cause severe personal injury or
property damage due to water and/or liquids:
* On gas control valves causing corrosion which
can result in gas leaks and fire or explosion from
the leak.
Clean all components of the heater with pressurized air, a
dry brush or a dry cloth.
Cleaning Instructions
WARNING
Fire, B
Burn, aand EExplosion H
Hazard
■
This heater contains components used in the gas management, and safety systems.
■
Such components may become inoperative or fail due to dust, dirt, wear and aging.
■
Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property
damage.