Start-Up Instructions
1. Slowly open the fuel gas supply valve.
2. Fully depress the button on the pilot safety control
valve while pushing the igniter button. The pilot will
light. See Fig. 2.
Fig. 2
ATTENTION
On new installations it may take a short time for gas to
purge out any air in the pilot line before the pilot stays lit.
3. Keep the pilot button depressed for about 30
seconds to allow the thermocouple to warmup so the
pilot stays lit after the pilot button is released.
4. Fully open the manual main burner valve located
between pilot safety control and burner, the main
burner will light.
WARNING
Burn H
Hazard
■
Close the manual main burner valve before lighting the
pilot.
■
Failure to do so will result in the main burner igniting
when the pilot is being lit.
■
Serious injury or death due to burns may occur.
PILOT GAS VALVE
PILOT BUTTON
PIEZO IGNITER
PIEZO
IGNITER
BUTTON
GAS INLET ELBOW
MAIN
BURNER
VALVE
THERMOCOUPLE
LEAD
Shut-Down Instructions
1. Close all fuel gas supply valves.
2. Allow the heater to burn off any fuel gas remaining on
the gas supply line.
3. Close the manual main burner valve on the heater.