beautypg.com

Manual shut-off valve, hose and regulator assembly – L.B. White AW250(building controller) User Manual

Page 11

background image

11

MANUAL SHUT-OFF VALVE, HOSE

AND REGULATOR ASSEMBLY

REGULATOR

NIPPLE

REGULATOR VENT

GAS HOSE

ADAPTER

SEDIMENT TRAP

TO CONTROL

VALVE INLET

GA

NIPPLE

VALVE, MANUAL
SHUT-OFF

1.

Always use approved pipe thread compound suitable
for use with L.P. gas or natural gas on the threaded
connections.

2.

Assemble the components together according to the
figure. This view is to show general assembly of the
components only. The regulator must always be
mounted so its vent, regardless of location on the
regulator, is always pointed downward.

3.

Tighten all connections securely.

4.

Check all connections for gas leaks using approved
gas leak detectors.

FIG. 6