13. Technical Specifications
Qualified Output Power:
> 0 dBm < +4.0 dBm @ 25
o
C Receive sensitivity Single Slot = -83 dBm with
0.1% BER
13.1. Storage and Operating Environment
13.1.1. Storage
Temperature: -10
o
C to +60
o
C
Humidity: 8% to 95% non-condensing
13.1.2. Operational
Temperature :
0
o
C to +40
o
C
Humidity
: 20% to 75% non-condensing
13.2. Power requirements
13.2.1. Input Voltage Requirements
The product was qualified using a fully rectified AC/DC power supply supplying 550mA @ 5V. To ensure your
product performs within the regulatory requirements, it is recommended that you use the AC/DC adapter supplied..
For your information only, the voltage range is given below. Minimum 5.0 V – Maximum 13.6 VDC NOTE: Power
supplied through Pin 9 of the RS 232 connector does go through the regulator and has the same input requirements
as the DC jack, +5.0 to 13.6 VDC.