beautypg.com

Cleaning the brew group – Philips RI9828-47 User Manual

Page 33

background image

31

1

8

9

2

5

6

7

3

4

The brew group must be cleaned at least once a week. Before removing the group, remove the coffee

dregdrawer as shown on page 30.

Wash the brew group with lukewarm water.

Lubricate the brew group after approximately 500 brewing cycles. The brew group lubricant can be purchased

through Saeco or authorized service centers.

WARNING! Do not wash the brew group with harsh or abrasive detergents or chemicals which could

prevent it from operating correctly. Do not wash in the dishwasher.

CLEANING THE BREW GROUP

Wash the brew group and the fi lter

and dry.

Press the PUSH button to remove

the brew group.

Lubricate the brew group guides

using the supplied lubricant.

Make sure the brew group is in rest

position; the two references must

match.

Make sure the components are in

the correct position. The hook

shown must be in the correct

position; to check its position,

fi rmly press the “PUSH” button.

Apply the lubricant evenly on both

side guides.

Insert the washed and dried brew

group. DO NOT PRESS THE “PUSH”

BUTTON.

Insert the dregdrawer.Close the

service door.

The lever on the rear part of the

group must be in contact with the

group base.