Physical specification – Philips 190S9FB-27 User Manual
Page 35
Product Information
Physical Specifications
• Tilt
-5°+2/-0 ~+ 20°+3/-0
• Power supply
100 ~ 240 VAC, 50/60 Hz
• Power consumption
36W* (typ.)
• Temperature
0° C to 40 ° C (operating)
-20° C to 60° C (storage)
• Relative humidity
20% to 80%
• System MTBF
50K hours (CCFL 40K hours)
* This data is subject to change without notice.
1280 x 1024, standard size, contrast 50%, brightness max., 6500° K, full white pattern.
Pin Assignment
1.The digital only connector contains 24 signal contacts organized in three rows of eight contacts. Signal pin assignments are listed in the following table:
Pin No. Signal Assignment
Pin No. Signal Assignment
Pin No. Signal Assignment
1
T.M.D.S. Data2-
9
T.M.D.S. Data1-
17 T.M.D.S. Data0-
2
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18 T.M.D.S. Data0+
3
T.M.D.S. Data2/4 Shield
11
T.M.D.S. Data1/3 Shield
19 T.M.D.S. Data0/5 Shield
4
No connect
12
No connect
20 No connect
5
No connect
13
No connect
21 No connect
6
DDC Clock
14
+5V Power
22 T.M.D.S. Clock Shield
7
DDC Data
15
Ground (for +5V)
23 T.M.D.S. Clock+
8
No connect
16 Hot Plug Detect
24 T.M.D.S. Clock-
file:///G|/TEMP/PHILIPS/190S9 EDFU/lcd/manual/ENGLISH/190S9/product/product.htm(第 7/9 页)2008-5-24 9:54:14