beautypg.com

Braun VISTA A2 User Manual

Page 9

background image

Page 7

,#$

Listed below are codes that the lift controller outputs
during lift operation. The codes will be displayed
on an LCD screen located on the lift control board
inside the pump module. See the Manual Operating
Instructions in the operator's manual for pump cover
removal instructions.

58 – Outboard barrier is not up and latched and the plat-

form is 3” above the ground

59 – Outboard barrier is not up after pausing platform

travel

75 – Low voltage detected; must turn off power switch to

reset LCD

77 – Vehicle secure interlock has not been activated
90 – Position will be set if you keep holding the button

until it beeps

91 – Position is out of a predetermined acceptable range

of floor position

92 – Bridge switch is not made, needs adjusting
93 – Inboard barrier occupied switch is not made, posi-

tion needs to be moved or switch should be ad-
justed

94 – Outboard barrier is not made, fix and try again
95 – Outboard barrier latch is not made (check for jumper

on Century and Vista lifts, check latch on Millennium
lifts)

99 – Controller program is not valid; replace controller

Flashing Numbers

Flashing 65 – Unfold button is pressed
Flashing 66 – Fold button is pressed
Flashing 67 – Down button is pressed
Flashing 68 – Up button is pressed
Flashing 69 – Bridge switch is activated
Flashing 70 – Outboard barrier latch switch is activated
Flashing 71 – Ground detect switch is activated
Flashing 72 – Outboard barrier up switch is activated
Flashing 73 – Inboard barrier up switch is activated
Flashing 74 – Inboard barrier occupied switch is acti-

vated

Flashing 76 – Outboard barrier occupied switch is
activated
Flashing 78 – Threshold tape switch “A” is activated
Flashing 79 – Threshold tape switch “B” is activated
Flashing 80 – Position set button is pressed

Non-Flashing Numbers

01 – Platform stowed
02 – Platform unfolding
03 – Platform unfolding paused
04 – Platform at floor level
05 – Platform beginning to lower
06 – Platform lowering (threshold cannot be occupied

from this point down)

07 – Outer barrier moving to horizontal position
08 – Platform at ground level
09 – Outer barrier moving to vertical position
10 – Platform raising
11 – Platform raising paused at floor
12 – Platform folding (limited pressure)
13 – Platform folding (full pressure)
14 – Timed fold (cinching lift tite) or (anti-rattle state)
15 – Platform folding stopped
16 – Paused fold
17 – Platform between ground and 3” above ground
18 – Platform above 3”
28 – Illegal function/not defined
29 – Interlock fault not recognized (or has been cleared

but a motion button is still pressed)

30 – Platform location unknown
31 – Platform location transition state; attempting to

locate position

50 – Outboard barrier is not up above inboard barrier

locked position

51 – Threshold is occupied when platform is 1” or more

below floor level

52 – Inboard barrier is not up and locked below inboard

barrier locked position

53 – Inboard barrier occupied sensor is not activated

between floor and inboard barrier up position

54 – Outboard barrier is occupied before it is up
55 – Outboard barrier is not latched when above the

inboard barrier locked position (Millennium only)

56 – Outboard barrier is not up and latched and bridge

switch did not deactivate

57 – Outboard barrier is not up and latched and ground

detect switch did not deactivate (Century and
Vista only)