Antenna grounding and safety warning

1. Outdoor antennas and lead-in conductors from antenna to a build-

ing, should not cross over open conductors of electric light or
power circuits.They should be kept away from all circuits to avoid
the possibility of accidental contact.

2. Each conductor of a lead-in from an outdoor antenna should be

connected with an antenna discharge unit. Antenna dicharge units
(or Lightning Arrestors) should be located outside the building or
inside the building between the point of entrance of the lead-in and
the TV, and as near as practical to the entrance of the conductors
to the building.

Important Safety Notes

If you do not feel comfortable or competent to install this antenna we

recommend that you seek the assistance of a qualified professional
antenna installer.

Read the instructions for this device thoroughly before attempting

installation.

The installation or dismantling of any antenna near power lines is dan-

gerous. Each year hundreds of people are killed or injured while
attempting to install or service antennas. For your safety and proper
antenna installation, read and follow all safety precautions.

Choose an installation site for safety as well as performance.
All electric power lines, cable lines and telephone lines look alike.To

be safe, assume ANY overhead line can kill you.

Do not place an antenna where it could potentially fall on to, or blow

into a power line. If in doubt call your electric provider. Let them
review your site.

Outdoor antennas should be grounded with an approved lighting arrest-

ing device. Local codes may apply. Use 8 AWG or larger ground wire.

Height or other restrictions on antennas may apply to your installa-

tion depending on your proximity to an airport, or local ordinances.

Take the time to plan your installation procedure. Do all assembly

EN

Safety Instructions

IIM

MP

PO

OR

RT

TA

AN

NT

T

R

RE

EA

AD

D

B

BE

EF

FO

OR

RE

E

IIN

NS

ST

TA

AL

LL

LA

AT

TIIO

ON

N

NEC -

National Electrical Code

* Antenna Discharge Unit is not required if lead in conductors are enclosed in a

continuous metallic shield that is permanently and effectively grounded.

GROUND CLAMP

ELECTRIC

SERVICE

EQUIPMENT

ANTENNA

LEAD-IN WIRE

ANTENNA

DISCHARGE

UNIT*

(NEC

SECTION

810-20)

GROUNDING

CONDUC-

TORS

(NEC SEC-

TION 810-

21)

GROUND CLAMPS

POWER SERVICE GROUND-

ING ELECTRODE

SYSTEM (NEC ART 250,

PART H)

TO EXTERNAL ANTENNA

TERMINALS OF PRODUCT

TO ROTATOR CONTROL UNIT