10-Gallon Tank with Eye Wash and Optional Heater Jacket
S19-690LHS, S19-690H

Installation Instructions

Bradley Corporation • 215-084 Rev. L; EN 02-586

4

Installation Instructions continued . . .

Step 2: Fill tank and pressurize

1. If the tank is pressurized, relieve the tank pressure by pulling up on the relief tank tab in the

center of the cover until the pressure gauge reads “0.”

IMPORTANT: DO NOT open the cover until the pressure gauge reads “0”!

2. Open the tank by pulling up on the wire handle located on top of the Quicklock cover. Push

down, rotate and remove. Fill the container with 7 gallons of potable water. Replace the cover.

3. Pressurize the tank to 95 PSI by applying air pressure to the valve located beneath the pressure gauge.

NOTE

: Relief valve is designed to automatically vent at 100-130 PSI to prevent the tank from over-

pressurizing.

Step 3: Flush tank

1. Discharge the water through the eye wash for at least five minutes to flush the system.

2. Refill the tank and pressurize as explained in Step 2 outlined above.

NOTE: Let unit stand for one hour. If there is a noticeable pressure drop, repressurize back to 95 PSI
and let stand for one hour. If problems persist, consult the Troubleshooting guide found on page 5.

NOTE: This unit will provide at least 15 minutes of cleansing action. Take the injured person immediately
to a normal emergency station for additional cleansing and treatment.

3. FOR OPTIONAL HEATER JACKET: Plug the jacket’s electrical cord into an electric outlet.

This manual is related to the following products: