Bryan indirect pool heaters – Bryan Boilers K Series User Manual
Page 4
Bryan Indirect Pool Heaters
Form No. 640 © 2004 Bryan Steam LLC
Printed in USA
44-5367
* Maximum outlet temperature for F series is 150°F; for DR, CLM, K and RV series, 160°. For outlet temperatures greater than those shown, consult factory.
† These units are equipped with two heat exchangers as standard and require a copper header to be field supplied.
F350-WP
280
576
16 x 36
40°F
23,000
350,000
350
NA
620
F450-WP
360
720
18 x 40
40°F
30,000
450,000
450
NA
765
F650-WP
520
1,000
20 x 50
40°F
40,000
650,000
650
NA
890
F850-WP
680
1,500
25 x 60
40°F
60,000
850,000
850
NA
1,155
DR350-WP
280
576
16 x 36
40°F
23,000
350,000
350
2.5
1,150
DR450-WP
360
720
18 x 40
40°F
30,000
450,000
450
3.2
1,250
DR650-WP
520
1,000
20 x 50
40°F
40,000
650,000
650
4.6
1,750
DR850-WP
680
1,500
25 x 60
40°F
60,000
850,000
850
6.1
1,850
CLM120-WP
960
1,800
30 x 60
40°F
84,000
1,200,000
1,200
8.6
3,200
CLM150-WP
1,200
2,250
30 x 75
40°F
92,000
1,500,000
1,500
10.7
3,600
CLM180-WP
1,440
3,000
40 x 75
40°F
123,000
1,800,000
1,800
12.9
4,050
CLM210-WP
1,680
3,465
42 x 80
40°F
137,000
2,100,000
2,100
15.0
4,475
CLM240-WP
1,920
4,050
45 x 90
40°F
143,000
2,400,000
2,400
17.1
4,900
CLM270-WP
2,160
5,000
50 x 100
40°F
160,000
2,700,000
2,700
19.3
5,525
CLM300-WP
2,400
6,000
60 x 100
40°F
184,000
3,000,000
3,000
21.4
5,930
K350-WP
2,800
6,600
60 x 110
40°F
217,000
3,500,000
3,500
NA
4,770
K400-WP
3,200
7,560
63 x 120
40°F
250,000
4,000,000
4,000
NA
5,180
K450-WP
3,600
8,400
70 x 120
40°F
275,000
4,500,000
4,500
NA
5,910
K500-WP †
4,000
9,750
75 x 130
40°F
320,000
5,000,000
5,000
NA
6,310
K550-WP †
4,400
12,000
75 x 160
40°F
400,000
5,500,000
5,500
NA
6,800
K600-WP †
4,800
13,200
80 x 165
40°F
445,000
6,000,000
6,000
NA
7,170
K650-WP †
5,200
14,000
80 x 175
40°F
490,000
6,500,000
6,500
NA
7,670
RV350-WP
2,800
6,600
60 x 110
40°F
217,000
3,500,000
3,500
25.0
7,375
RV400-WP
3,200
7,500
63 x 120
40°F
250,000
4,000,000
4,000
28.6
8,100
RV450-WP
3,600
8,400
70 x 120
40°F
275,000
4,500,000
4,500
32.1
8,320
RV500-WP †
4,000
9,750
75 x 130
40°F
320,000
5,000,000
5,000
35.7
9,080
RV550-WP †
4,400
12,000
75 x 160
40°F
400,000
5,500,000
5,500
39.3
9,820
RV600-WP †
4,800
13,600
80 x 165
40°F
490,000
6,000,000
6,000
42.9
10,530
RV700-WP †
5,600
14,800
80 x 185
40°F
575,000
7,000,000
7,000
50.0
11,960
RV800-WP †
6,400
15,000
100 x 150
40°F
600,000
8,000,000
8,000
57.1
13,450
Pool Heater Sizing
Input Firing Rates
F SERIES
(Atmospheric)
DR SERIES
(Forced Draft)
CLM
SERIES
(Atmospheric
or Forced
Draft)
K SERIES
(Atmospheric)
Bryan Steam LLC — Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet: www.bryanboilers.com
Fax: 765-473-3074 • E-mail: [email protected]
Approximate
Shipping
Weights (lbs)
Heater
Output
MBH
RV SERIES
(Forced Draft)
Heater
Series
Model
Number
Surface Area
Method
Pool
Surface
Area Sq. Ft.
Pool
Size
W x L ft.
Water
vs
Air Temp.
Pool
Gallonage
(Approx.)
Time Rise
Method
BTU's
Ft
3
Nat
Gas
Gallons
Oil
Per Hour
Indirect heat exchanger,
combina-
tion thermometer and pressure gauge,
ASME-rated boiler relief valve, water
temperature control (240°F max. std.),
high limit control, probe LWCO, pool
water temperature controller, expansion
tank, fill and stop valve.
Atmospheric equipment
Electronic combustion safety control,
automatic operating gas valve, safety
gas valve, pilot solenoid valve, electric
ignition assembly, main manual gas
shut-off valve, pilot shut-off valve, pilot
and main gas pressure regulators, draft
controller, all controls installed and wired
standard voltage 120/1/60.
When ordering, please specify:
1. Boiler size
2. Supply and return
temperatures required
3. Boiler relief valve setting
4. Type of fuel: natural, LP,
or other gas and/or No. 2 oil
5. If gas, type, BTU content,
specific gravity and pressure
available
6. Electric power voltage,
phase and frequency
7. Optional extra equipment
or construction
8. Special approvals required
(UL, CSD-1, FM, or IRI)
9. Altitude
OPTIONAL EQUIPMENT:
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
4. Combination low water cutoff
and feeder
5. Alarm bells or horns
6. CSD-1, FM, IRI or other insurance
approved control systems
7. Indicating lights, as desired
8. Lead-lag systems for two or more
boilers with or without outdoor
reset control
9. Draft control system
STANDARD EQUIPMENT :
Bryan Indirect Pool Heaters Standard and Optional Equipment
Forced Draft Equipment
Straight oil fired unit Electronic com-
bustion safety control, oil valve, oil igni-
tion transformer, two-stage fuel unit,
direct spark ignition, oil nozzle assembly,
control panel, all controls installed and
wired.
Combination gas-oil unit Electronic
combustion safety control, automatic
operating gas valve, safety gas valve,
pilot solenoid valve, pilot ignition
assembly, main manual gas shut-off
valve, pilot cock, pilot and main gas
pressure regulators, air safety switch,
manual fuel selector switch, oil valve,
gas pilot for both fuels, two-stage fuel
unit, oil nozzle assembly, control panel,
all controls installed and wired.
Straight gas fired unit Electronic com-
bustion safety control, automatic oper-
ating gas valve, safety gas valve, pilot
solenoid valve, pilot ignition assembly,
main manual gas shut-off valve, pilot
cock, pilot and main gas pressure regu-
lators, air safety switch, control panel,
all controls installed and wired.