TROUBLESHOOTING (cont.)
BREW CIRCUIT

PROBLEM

PROBABLE CAUSE

REMEDY

Refer to

Adjustments and Optional

Settings

to set brew volume. See

page 7. Using a stop watch or sec-
ond hand, time the length of the
brew cycle. Record this time inside
the top lid. If service is ever needed
again, use the time as reference to
determine if time has changed.

Inspect the sprayhead tube and
sprayhead for excessive lime de-
posits. Delime as required.

Refer to

Service -

Brew Solenoid

Valves for testing procedures. See
pages 16 or 17

Refer to

Service -

Dilution Solenoid

Valve for testing procedures. See
page 18

1. Brew volume (TEA or COFFEE)
NOTE: All volumes to run with
sprayhead attached.

2. Lime build up

3. Brew Solenoid Valves

4. Dilution Solenoid Valve

Consistently low beverage level in
the dispenser or beverage over-
flows dispenser

29466 082200