Specifications, General data transceiver, Receiver specifications – Becker Designed AR 3201 User Manual
Page 9

1.5
Specifications
1.5.1
General data Transceiver
Operating voltage
12,4 V . . . 15,1 V
Emergency operation (10,0 V)
Intelligible communication
Current consumption 14 V without
Panel illumination
Receive ,, stand by ‘‘
typ. 70 mA
Receive ,, stand by ‘‘ with auxiliary input
typ. 90 mA
Transmit
typ. 1 .8 A
Panel illumination
13,8 V / 40 mA DC
Fuse
5A
Operating temperature range
D1 - 20° . . .+ 55°C,
Env. Cat. RTCA DO - 160A
shorttime temperature + 70°C
Altitude max.
D1 50000 ft
Env. Cat. RTCA DO - 160A
Vibration
MNO
Env. Cat. RTCA DO - 160A
Dimensions
Panel
60.6 mm x 60.6 mm
Mounting depth
212.5 mm
Weight
0.9 kg
1.5.2
Receiver specifications
Type Receiver
Single superhet
Frequency range
118.000 MHz . . . 136.975 MHz
Channels
760
Channel spacing
25 kHz
Sensitivity (mod. 1000 Hz/30%)
≤
5
µ
V emf for 6 dB S+N
N
Bandwidth
≥ ±
8 kHz at 6 dB down
Selectivity
≥
40 dB at
±
17 kHz
≥
60 dB at
±
25 kHz
AR 3201 - ( )
DV 28110.03/.04 Issue 04/92