Installation – Belkin F1DW116C User Manual
Page 15

13
INSTALLATION
DIP SWITCH #
BANK ADDRESS
1
2
3
4
DOWN
DOWN
DOWN
DOWN
BANK 00 (Default)
UP
DOWN
DOWN
DOWN
BANK 01 PRIMARY/SECONDARY
DOWN
UP
DOWN
DOWN
BANK 02 SECONDARY
UP
UP
DOWN
DOWN
BANK 03 SECONDARY
DOWN
DOWN
UP
DOWN
BANK 04 SECONDARY
UP
DOWN
UP
DOWN
BANK 05 SECONDARY
DOWN
UP
UP
DOWN
BANK 06 SECONDARY
UP
UP
UP
DOWN
BANK 07 SECONDARY
DOWN
DOWN
DOWN
UP
BANK 08 SECONDARY
UP
DOWN
DOWN
UP
BANK 09 SECONDARY
DOWN
UP
DOWN
UP
BANK 10 SECONDARY
UP
UP
DOWN
UP
BANK 11 SECONDARY
DOWN
DOWN
UP
UP
BANK 12 SECONDARY
UP
DOWN
UP
UP
BANK 13 SECONDARY
DOWN
UP
UP
UP
BANK 14 SECONDARY
UP
UP
UP
UP
BANK 15 SECONDARY
Example:
Four OmniView ENTERPRISE Quad-Bus Series KVM Switches (F1DW216C) are
daisy-chained together to control 64 computers. The DIP switch on the primary units
are set to “BANK Address 00” and “BANK Address 01” and the secondary units are
each set to a unique BANK address between 02 and 15 (BANK 00 needs to be
configured for daisy-chain operation, as noted above).
Installation
Before you begin:
1. Make sure that all computers and switches are powered off and that each Switch
has been assigned a unique BANK address.
2. Place primary and secondary Switches in the desired locations.
DIP Switch Configuration Chart
P74342_F1DWXXXC_man.qxd 12/5/03 3:14 PM Page 13