Automatic safety and control devices of the oven, Protection of the auxiliary electrical circuit, Protection of the chamber fan – Bakers Pride MT-200 User Manual
Page 12: Oven chamber safety thermostat

Convection Oven
Installation
10
Automatic Safety and Control Devices of the Oven
Protection of the Auxiliary Electrical Circuit
It is checked by the fuses positioned on a terminal block at the line entry.
Protection of the Chamber Fan
A remote switch stops the fan motor in the event of a malfunction or overload. It is located behind the
oven and must be reset manually. When it cuts in, it stops the motor and shuts off the heating elements.
Oven Chamber Safety Thermostat
The safety thermostat disconnects the heating elements if the temperature in the oven chamber is too
high (644°F). It must be reset manually. If it activates, technical service must be notified. All components
are protected by the following type of fuse: CLASS CC,G 600V 20A.