Liebherr WTes 5872 Vinidor User Manual
Page 4
06-07_LaborSpecial.indd 6
25.02.14 13:52
7
Cal.1 1.0°C 0.5°C Cal.2 8.0°C -0.4°C Cal.3 15.0°C 0.8°C
+0.5°C
-0.4°C
+0.8°C
06-07_LaborSpecial.indd 7
25.02.14 13:52
Innovative expertise and drive in the
laboratory sector
T
he demands made on refrigerators and freezers are particularly
high in all the sectors of professional use. Whether the issue is
the refrigeration performance, specifying the materials, designing
the refrigeration components or evolving the design concepts – all
the decisions are directed to ensuring the long-term, trouble-free
use of our appliances.
The most stringent reliability and safety standards apply to appliances
in the laboratory sector. Therefore Liebherr has a range of purpose-
built and factory-designed laboratory appliances in different
temperature ranges for numerous applications. The MediLine
appliances incorporating Profi electronic controllers offer many
advantages. High-grade materials, high-performance components
and accurate workmanship right down to the last detail ensure the
high quality of the Liebherr appliances.
06-07_LaborSpecial_EN.indd 6
11.02.14 13:01
The Profi electronic controller
The menu-guided Profi electronic controller with integrated real-time clock allows the temperature to
be set to 1/10°C accuracy. The text display has German, English, French, Spanish or Italian language
setting options. To satisfy laboratory hygiene requirements, the electronic controller is fl ush-fi tted and
has an easy-clean membrane keypad.
Mains-independent power supply of the electronic controller
In case of power failure, the electronic controller continues to operate from an integrated 12 V battery.
As a result, the memory continues to log the internal temperatures for another 72 hours even in the
event of power failure. Furthermore, if external alarm and documentation systems are connected, the
data transfer is maintained for as long as 72 hours.
Integrated alarm systems
A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. In
addition, a visual and audible alarm is activated if the door is open for longer than 1 minute. There is
also an immediate visual and audible alarm in the event of power failure.
Integrated data memory
The Profi electronic controller has an integrated data memory which logs the last 30 alarm events
including date, time and maximum temperature as well as the internal temperature profi le at 4-minute
intervals. 2800 temperature logs are stored to memory, which corresponds to approximately a 7-day
logging period.
3-point calibration
The laboratory appliances with Profi electronic controllers provide 3-point calibration for extremely
accurate temperature control. This permits compensation between the set temperature and the actual
internal temperature at as many as three temperature points. Positive or negative changes to the
correction value can be made in steps of 0.1K.
The laboratory refrigerators and freezers
with Profi electronic controllers
72 hours
06-07_LaborSpecial_EN.indd 7
11.02.14 13:01
- WKr 1811 Vinothek GG 5210 FKDv 3713 Premium GGPv 1470 ProfiLine ZKes 453 Humidor WTes 5972 Vinidor WKes 653 Grand Cru GG 4010 G 5216 WKt 4551 GrandCru WKt 5551 GrandCru MKv 3910 GGv 5810 GGv 5010 BCDv 1003 GG 4060 FT 2900 WKb 1812 Vinothek WKb 3212 Vinothek FDv 4613 FT 2902 GG 5260 GGU 1500 Premium WTr 4211 Vinothek WKt 4552 GrandCru GGPv 1490 ProfiPremiumline WKb 4212 Vinothek WKr 3211 Vinothek WTpes 5972 Vinidor WKr 4211 Vinothek WKt 5552 GrandCru BCDv 4313 GGU 1550 Premium WTb 4212 Vinothek WKes 4552 GrandCru GGPv 6570 ProfiLine GGv 5060 GGPv 6590 ProfiPremiumline GGv 5860 MKUv 1610 WKt 6451 GrandCru Fv 3613