GENERAL NOTES

WORCESTER BOSCH GREENSTAR 25CDi/30CDi/35CDi/40CDi

6 720 611 928a (02/05)

10

BOILER CLEARANCES -
UNVENTILATED COMPARTMENT

The diagrams (A and B) opposite show
two options for the minimum space
required to install and service the boiler
inside an unventilated compartment.

* This space can be reduced to 50 mm
for one side only as long as both the
side clearances add up to the total of
both the side measurements shown or
more.

** Space required for unventilated areas
with a removable door or panel.

*** 600 mm clearance required to a fixed
surface for servicing.

ROOM THERMOSTAT

A room temperature controller and pro-
grammer should be fitted to control the
central heating. Refer to the instructions
supplied with the thermostat for informa-
tion on siting and setting.

THERMOSTATIC RADIATOR VALVES

It is recommended that this type of valve
is fitted to all but one of the radiators (or
at least those in the sleeping accommo-
dation). The remaining radiator, which
must be where the room thermostat is
located, should be uncontrolled and
must be left open. The thermostatic
radiator valves should conform to the
requirements of BS2767:10.

+ 30mm

above elbow

200mm*

200mm*

100mm**

600mm***

200mm