beautypg.com

Relief valve selections, Rw series water boilers – Bryan Boilers Water Boiler User Manual

Page 15

background image

Bryan Steam, LLC
Engineering Section

RELIEF VALVE SELECTIONS

Form 2284

1/21/2005

H.S.

Boiler Model Pressure

Part #

Model

Qty.

Size

Actual Cap. Actual Cap.

Vendor

(Psig)

Per Valve

Total

(MBH)

(MBH)

1118

RW850

30#

26138

740

3

2x2½

5250

15750

Watts

45#

26141

740

2

2x2½

7067

14134

Watts

50#

26142

740

2

2x2½

7672

15344

Watts

60#

94046

740

2

2x2½

8883

17766

Watts

75#

94038

740

2

1½x2

5909

11818

Watts

125#

26200

174A

2

1½x1½

6460

12920

Watts

150#

94054

174A

2

1¼x1¼

6340

12680

Watts

1266

RW1050

30#

26138

740

3

2x2½

5250

15750

Watts

45#

26141

740

2

2x2½

7067

14134

Watts

50#

26142

740

2

2x2½

7672

15344

Watts

60#

26135

740

2

2x2½

8883

17766

Watts

75#

94048

740

2

2x2½

10700

21400

Watts

125#

26200

174A

2

1½x1½

6460

12920

Watts

150#

94058

174A

2

1½x1½

7630

15260

Watts

1527

RW1260

30#

26138

740

3

2x2½

5250

15750

Watts

45#

26141

740

3

2x2½

7067

21201

Watts

50#

26142

740

2

2x2½

7672

15344

Watts

60#

94046

740

2

2x2½

8883

17766

Watts

75#

94048

740

2

2x2½

10700

21400

Watts

125#

94062

174A

2

2x2

12170

24340

Watts

150#

94054

174A

3

1¼x1¼

6340

19020

Watts

1787

RW1500

30#

26138

740

4

2x2½

5250

21000

Watts

45#

26141

740

3

2x2½

7067

21201

Watts

50#

26142

740

3

2x2½

7672

23016

Watts

60#

94046

740

3

2x2½

8883

26649

Watts

75#

94048

740

2

2x2½

10700

21400

Watts

125#

94062

174A

2

2x2

12170

24340

Watts

150#

94064

174A

2

2x2

14370

28740

Watts

2048

RW1700

30#

26138

740

4

2x2½

5250

21000

Watts

45#

26141

740

3

2x2½

7067

21201

Watts

50#

26142

740

3

2x2½

7672

23016

Watts

60#

94046

740

3

2x2½

8883

26649

Watts

75#

64048

740

2

2x2½

10700

21400

Watts

125#

94062

174A

2

2x2

12170

24340

Watts

150#

94064

174A

2

2x2

14370

28740

Watts

2308

RW1900

30#

26138

740

5

2x2½

5250

26250

Watts

45#

26141

740

4

2x2½

7067

28268

Watts

50#

26142

740

4

2x2½

7672

30688

Watts

60#

94046

740

3

2x2½

8883

26649

Watts

75#

94048

740

3

2x2½

10700

32100

Watts

125#

94062

174A

2

2x2

12170

24340

Watts

150#

94064

174A

2

2x2

14370

28740

Watts

2569

RW2100

30#

26138

740

5

2x2½

5250

26250

Watts

45#

26141

740

4

2x2½

7067

28268

Watts

50#

26142

740

4

2x2½

7672

30688

Watts

60#

94046

740

3

2x2½

8883

26649

Watts

75#

94048

740

3

2x2½

10700

32100

Watts

125#

94062

174A

3

2x2

12170

36510

Watts

150#

94064

174A

2

2x2

14370

28740

Watts

RW Series Water Boilers

Sheet: RW-W
FIle: Form 2284.XLS

Page 15 of 15