beautypg.com

Operation – Briggs & Stratton 209443gs User Manual

Page 12

background image

Operation

Starting the Engine

Disconnect all electrical loads from the generator. Use the
following start instructions:

1. Make sure unit is on a level surface.

NOTICE

Failure to start and operate the unit on a level

surface will cause the unit not to start or shut down during
operation.

2. Turn the fuel valve (

A) to the “On” position.

3. Push choke lever to “

Choke” position.

4. Push engine rocker switch to “

On”.

5. Grasp recoil handle and pull slowly until slight

resistance is felt. Then pull handle rapidly to overcome
compression, prevent kickback, and start engine.

NOTICE

If excessive fuel is present in the air/fuel mixture

causing a “flooded” condition, move the choke lever to

Run” position and pull the handle repeatedly until the

engine starts.

6. Move choke lever to “

Run” position a short distance at

a time over several seconds in warm weather or
minutes in cold weather. Let engine run smoothly
before each change. Operate with choke in “

Run

position.

NOTICE

If the engine starts after 3 pulls but fails to run, or

if the unit shuts down during operation, make sure the unit
is on a level surface and check for the proper oil level in the
crankcase. This unit may be equipped with a low oil
protection device.

12

BRIGGSandSTRATTON.COM

A

WARNING Starter cord kickback (rapid retraction) can

result in bodily injury. Kickback will pull hand and

arm toward engine faster than you can let go.

Broken bones, fractures, bruises, or sprains

could result.

• When starting engine, pull cord slowly until resistance is felt

and then pull rapidly to avoid kickback.

• NEVER start or stop engine with electrical devices plugged in

and turned on.

WARNING Contact with muffler area can result in

serious burns.

Exhaust heat/gases can ignite

combustibles, structures or damage

fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 5 feet (152 cm) of clearance on all sides of

generator including overhead.

• It is a violation of California Public Resource Code, Section

4442, to use or operate the engine on any forest-covered,

brush-covered, or grass-covered land unless the exhaust

system is equipped with a spark arrester, as defined in Section

4442, maintained in effective working order. Other states or

federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer, or dealer

to obtain a spark arrester designed for the exhaust system

installed on this engine.

• Replacement parts must be the same and installed in the same

position as the original parts.