beautypg.com

Features, Technical data preparation, Intended use – Bosch GPL5 User Manual

Page 6

background image

-6-

The numbering of the product features shown
refers to the illustration of the tool on the
graphic page.

1 Exit opening for laser beam
2 Latch of battery lid
3 Battery lid
4 On/Off switch
5 Laser warning label
6 Tripod mount 5/8-11
7 Serial number
8 Multi-Purpose Attachment
9 Locking screw for Multi-Purpose

Attachment

10 Screw holes of Multi-Purpose

Attachment

11 Opening for strap attachment
12 Magnets
13 1/4-20 tripod mount on Multi-Purpose

Attachment

14 5/8-11 tripod mount on Multi-Purpose

Attachment

15 Measurement plate with stand*
16 Protective Case “not shown”
17 Laser viewing glasses
18 Tripod*

*The accessories illustrated or described are
not included as standard delivery.

Features

Working range (typical)

100 ft (30m)

Leveling Accuracy

Minimum Factory
Accuracy

+/- 0.3mm/m (0.0036in/ft)

Typical Accuracy

up to 1/4 at 100 ft

Self-leveling range (typical) alongside the
– longitudinal axis

up to ±5°

– lateral axis

±3°

Operating temperature 14 °F... 122 °F

(–10 °C ... +50 °C)

Storage temperature -4 °F... 158 °F

( –20 °C ... +70 °C)

Relative air humidity,
max. 90

%

Laser class

II

Laser type

635 nm, <1 mW

Tripod mount

5/8-11

Batteries

4 x 1.5 V LR6 (AA)

Operating lifetime, approx.

24 h

Weight according to EPTA-Procedure

01/2003 1.6lb

(725g)

Dimensions

5.7” x 4.3” x 2.4”

(143x 110 x 60mm)

Please observe the article number on the
type plate of your tool. The trade names of
the individual tools may vary.

The tool can be clearly identified with the
serial number 7 on the type plate.

Technical Data

Preparation

Inserting/Replacing the Battery

Alkaline batteries are recommended for
the tool.

To open the battery compartment 3, turn the
latch 2 in clockwise direction to position
and pull off the battery lid. Insert the batteries
provided.

When inserting, pay attention to the correct
polarity according to the representation on
the inside of the battery compartment.

Position the battery lid to the bottom of the
housing and then push it upward. To lock the
battery lid, turn the latch 2 in

counterclockwise direction to the position.

When the laser beams flash slowly during
operation,the batteries are low. When the
flashing begins, the tool can be operated for
approx. 8 h.

Always replace all batteries at the same time.
Only use batteries from one brand and with
the identical capacity.

Remove the batteries from the

tool when not using it for extended
periods.
When storing for extended
periods, the batteries can corrode and
discharge themselves.

This tool projects plumb and horizontal points and is intended for accurate transfer and

alignment of plumb, level, graded and 90-degree points

Intended Use