Replace the nozzle using the conversion set
supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching nozzles to burners.

Adjust the primary airflow by loosening the screw
P and setting the gap X in the Venturi cone to
5/16” for natural gas (1/2” for LP gas).

STEP 4: BROILER BURNER

Loosen the screw and pull out the burner from its
support.

ATTENTION: pay extra attention to avoid damage
to the igniter and thermocouple.

Using a 7 mm [name of the tool] unscrew the
nozzle. Replace the nozzle using the conversion
set supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching nozzles to burners.

Adjust the gap X by setting it to fully open
position.