beautypg.com

Regulation of burners, Adapting to different types of gas, Primary air adjustment – Bertazzoni X304GGVNE User Manual

Page 12

background image

12

Models X304GGVX [M7S0GTU4X (2 or 5)A]

Adapting to different types of gas

CAUTION: save the orifices removed from the appliance for future use

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By-pass

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary

Rear L

0,90

NG

4”

3400

996

900

264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Front R

1,18

NG

4”

6100

1787

1500

439

Regulated

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid

Rear R

1,55

NG

4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP

(Propane)

11”

2800

820

900

264

0,29

Front L Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Oven

Oven 1,85 NG 4”

14500

4248

3500

1025

Regulated

downside 1,10

LP

(Propane)

11”

14500

4248

3500

1025 0,54

Broiler

Oven

1,70

NG

4”

12000

3516

Only Max

Only Max

No by-pass

upside

0,98

LP (Propane)

11”

12000

3516

Only Max

Only Max

No by-pass

REGULATION OF BURNERS

Primary air adjustment:

Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone
according to the measurements indicated in table 4.



TABLE N°4: Burner primary air regulation (indicative)

Burner
Type of gas

Broiler

Inches

(mm)

NG (Natural Gas)

fully open

LP (Propane Gas)

fully open


Work surface burner adjustment
: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body
and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

Oven burner adjustment: follow the instructions below to adjust the minimum:
1) Light the burner setting the knob to the MAXIMUM position.
2) Close the oven door and operate the oven for at least 10 minutes.
3) Set the knob to the MINIMUM position and then remove it.
4) With a slotted screwdriver turn the choking screw (by-pass screw at the left side of the thermostat bar) and, while
observing the flame at the same time through the cooker porthole, evaluate the consistency of the flame so it remains on
when switching quickly from the MINIMUM to the MAXIMUM position.
WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with

liquid gas the screw must be locked at the end in a clockwise direction. The broiler burner always
operates at maximum and therefore no minimum adjustment is required.

This manual is related to the following products: