beautypg.com

Performance data sheet, Water filtration system – Whirlpool WRX988SIBM User Manual

Page 30

background image

30

PERFORMANCE DATA SHEET

Water Filtration System

Model P6WB2L/P6RFWB2 Capacity 200 Gallons (757 Liters)

Model P6WB2NL/P6RFWB2 Capacity 200 Gallons (757 Liters)

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.43 gpm (1.6 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is important that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised. Property damage can occur if all
instructions are not followed.

Use replacement filter P6RFWB2, part #W10413645A.
2013 suggested retail price of $39.99 U.S.A./$49.99 Canada.
Prices are subject to change without notice.
Style 1 – When Order Filter is illuminated yellow, order a new
filter. When Replace Filter is illuminated red, it is recommended
that you replace the filter.
Style 2 – Press OPTIONS and select Filter Status to check the
status of your water filter. When the filter status shows 10%
remaining, order a new filter. When the filter status shows 0%
remaining, it is recommended that you replace the filter.
Style 3 – Press FILTER STATUS to check the status of your water
filter. When the filter status shows 10% remaining, order a new
filter. When the filter status shows 0% remaining, it is
recommended that you replace the filter.

After changing the water filter, flush the water system. See
“Water and Ice Dispensers” or “Water Dispenser” in the User
Instructions or User Guide.

These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.

The product is for cold water use only.

The water system must be installed in compliance with state and
local laws and regulations.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.

Refer to the “Warranty” section (in the User Instructions or User
Guide) for the Manufacturer’s name, address and telephone
number.

Refer to the “Warranty” section (in the User Instructions or User
Guide) for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Minimum %
Reduction

Average %
Reduction

Chlorine Taste/Odor
Particulate Class I

*

50% reduction
85% reduction

2.0 mg/L
7,300,000 #/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.20 mg/L
75,000 #/mL

**

97
99

97.2
99.4

Contaminant
Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Minimum %
Reduction

Average %
Reduction

Live Cysts

99.95%

160,000/L

50,000/L min.

54/L

99.97

99.99

Asbestos

99%

87 MFL

10

7

to 10

8

fibers/L

††

0.17 MFL

99

99

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

0.160 mg/L
0.140 mg/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.001 mg/L
0.005 mg/L

99.4
98.6

99.4
98.6

Lindane

0.0002 mg/L

0.0019 mg/L

0.002 mg/L ± 10%

0.00002 mg/L

98.9

99

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 mg/L ± 10%

0.001 mg/L

93

93

Atrazine

0.003 mg/L

0.0094 mg/L

0.009 mg/L ± 10%

0.0005 mg/L

94.5

94.7

2,4 - D

0.07 mg/L

0.220 mg/L

0.210 mg/L ± 10%

0.028 mg/L

87.5

96.1

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.43 gpm (1.6 Lpm) @ 60 psi

*

**

††

Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length

® NSF is a registered trademark of NSF International.