beautypg.com

Care and maintenance, Humidifying filter – Sharp KC-930EU-W User Manual

Page 14

background image

E-12

Frequency of maintenance cycle will depend on the hardness or the impurities of the water that

you use; the harder the water the more often descaling will be necessary.
Pay attention not to spill water when cleaning the fi lter.

1

Remove the Water Tank and

Humidifying Tray.

(See E-11)

2

Remove the Humidifying Filter

from the Humidifying Tray.

Avoid spilling water from the Humidifying

Tray.

3

Preparing the descaling solu-

tion.

Citric acid, available at some drugstores,

or 100 % bottled lemon juice are used for

descaling. Choose either one to use, and

prepare the descaling solution.

Dissolve 3 teaspoons of citric acid and 2

1/2 cups of lukewarm water in a suitable

container, and stir well.

100 % bottled lemon juice can be used

for descaling. Use only 100 % bottled

lemon juice with no pulp (strain juice if

necessary). Combine 1/4 cup lemon juice

and 3 cups of lukewarm water in a con-

tainer large enough to hold the Humidify-

ing Filter and stir well.

4

When using lemon juice, it is recommend-

ed to pre-soak longer than citric acid.

5

Rinse the Humidifying Filter re-

peatedly with lukewarm water

to remove all the solution resi-

due.

Inadequate rinsing may cause odour and

affect the performance and/or appear-

ance of the unit.
* Do not scrub the Hu-

midifying Filter, rinse

gently under lukewarm

water only.

6

Attach the Humidifying Filter

to the Humidifying Tray, and

replace the Humidifying Tray in

the unit.

• T h e H u m i d i f y i n g F i l t e r d o s e n o t

need to be oriented in any particular

position(forward/backward, up/down)

7

Plug in the unit, turn power

ON, and press the Filter Reset

Button on the display for more

than 3 seconds to reset.

HUMIDIFYING FILTER

Care Cycle

Once a month or when the Filter Indicator Light is on.

Pre-soak the Humidifying Filter

in the solution for 30 minutes

before cleaning.

CARE AND MAINTENANCE

You may notice reddish-brown or

white deposits forming on the surface

of the Humidifying Filter. These impu-

rities (calcium, etc.) are due to the im-

purities contained in tap water; this is

not a defect. Replace the Humidifying

Filter when it is covered completely in

white deposits.

•When not using

the unit for a long

periods of time,

dry the Humidify-

ing Filter com-

p l e t e l y b e f o r e

replacing.

When cleaning the unit, be sure to fi rst unplug the power cord, and never handle the plug with

wet hands. Electrical shock and/or bodily injury may occur as a result.

KC-930EU_eng.indd 14

KC-930EU_eng.indd 14

2009/09/11 11:11:02

2009/09/11 11:11:02