Reduced spray or no spray
Possible Causes
Remedies
Clean Water Tank Assembly empty
Refill Tank
Spray Nozzle clogged
Clean Spray Nozzle
Pump not operating properly
Check electrical plug
Power switch on?
Turn POWERSTEAMER
®
off and hold
Trigger for 10-15 seconds. Turn Power
Switch to“CLEAN” position and hold
trigger for10-15 seconds
Call BISSELL Consumer Services
Vacuum not picking up cleaning solution
Possible Causes
Remedies
Loose Triangle Cap
Check cap and snap securely into Dirty
Water Tank Assembly
Dirty Water Tank Assembly
Check Tank for proper alignment and
not aligned/secured
secure with side latches
Flex Hose Assembly not secure
Check fit of Hose at Vacuum Port
connections
Poor Tool position
Adjust angle; apply more downward
pressure
Dirty Water Tank Assembly is full
Empty Dirty Water Tank Assembly
Troubleshooting