beautypg.com

Warning – Bosch 9000063716 (8504) User Manual

Page 16

background image

14

• Do not pre-twist the wires before connecting them

with wire nuts.

• Extend the dishwasher’s stranded wires 1/8” (3mm)

beyond the power supply cable’s solid wires, as
shown in Figure 30.

5 Using the supplied wire nuts, connect the electrical

supply wires to the dishwasher’s wires, black to black,
white to white, and green or bare. Make certain that
the insulated wires show no bare wire from the
bottoms of the wire nuts. Gently tug the wires to make
certain they are securely connected.

6 Press the wires into the junction box as shown in

Figure 31. Make certain that the wire nuts do not
loosen.

7 Place the cover on the junction box and secure it to

the junction box with the supplied screw.

DOOR TENSION ADJUSTMENT (only on SHI
and SHV models with custom door panels)

After the dishwasher and custom door panel are installed,
open and close the door several times to make sure that
it does so with ease. If the door falls open too quickly,
the spring tension needs to be adjusted.

To Adjust the Spring Tension:
1
Obtain the provided Spring Tension Screws from the

SHI/SHV Door Panel Installation Kit.

2 Insert the screws as shown in Figure 32. Turning the

screw clockwise increases the spring tension.

TOE PANEL INSTALLATION

Regular Toe Panel Installation
Use the toe panel screws from the Dishwasher Installa-
tion Kit and a T-20 screwdriver to install the toe panel as
shown in Figure 33.

Figure 30

ELECTRICAL CONNECTION (continued)

Figure 32

Figure 33

1/8”
3mm

Electrical Connection/ Door Tension Adjustment/ Base and Toe Panel

Fire Hazard

To avoid a fire hazard, make sure there are no
loose electrical connections. Make sure all
electrical connections are properly made.

WARNING

Figure 31

This manual is related to the following products: