14
• Do not pre-twist the wires before connecting them
with wire nuts.
• Extend the dishwasher’s stranded wires 1/8” (3mm)
beyond the power supply cable’s solid wires, as
shown in Figure 30.
5 Using the supplied wire nuts, connect the electrical
supply wires to the dishwasher’s wires, black to black,
white to white, and green or bare. Make certain that
the insulated wires show no bare wire from the
bottoms of the wire nuts. Gently tug the wires to make
certain they are securely connected.
6 Press the wires into the junction box as shown in
Figure 31. Make certain that the wire nuts do not
loosen.
7 Place the cover on the junction box and secure it to
the junction box with the supplied screw.
DOOR TENSION ADJUSTMENT (only on SHI
and SHV models with custom door panels)
After the dishwasher and custom door panel are installed,
open and close the door several times to make sure that
it does so with ease. If the door falls open too quickly,
the spring tension needs to be adjusted.
To Adjust the Spring Tension:
1 Obtain the provided Spring Tension Screws from the
SHI/SHV Door Panel Installation Kit.
2 Insert the screws as shown in Figure 32. Turning the
screw clockwise increases the spring tension.
TOE PANEL INSTALLATION
Regular Toe Panel Installation
Use the toe panel screws from the Dishwasher Installa-
tion Kit and a T-20 screwdriver to install the toe panel as
shown in Figure 33.
Figure 30
ELECTRICAL CONNECTION (continued)
Figure 32
Figure 33
1/8”
3mm
Electrical Connection/ Door Tension Adjustment/ Base and Toe Panel
Fire Hazard
To avoid a fire hazard, make sure there are no
loose electrical connections. Make sure all
electrical connections are properly made.
WARNING
Figure 31