Bryan ab series steam & hot water boilers – Bryan Boilers AB250-S150-FDG User Manual
Page 4
Bryan Steam LLC — Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651 • Internet:www.bryanboilers.com
Fax: 765-473-3074 • E-mail: [email protected]
Bryan AB Series Steam & Hot Water Boilers
Specifi cations subject to change without notice. Consult factory to consult on other boiler options.
Form No. 7510 ©2005 Bryan Steam LLC
Printed in USA
65-7097
STEAM BOILER DIMENSIONS — inches (cm)
A
B
C
D
E
F
G
H
I
J
K
L
Boiler Length
Width
Height Gas
Train
Supply
Clearance for Min. Tube Floor to
Model
of Outside
Over
Overall
Connection
Nozzle
Return Flue
Flue
Servicing Removal
Flow
Number Jacket Jacket
Jacket
Length
(Approx.)
15 psi
150 psi
Conn. Size Location
Burner Clearance
Nozzle
AB-90
44
15
/
16
38
1
/
2
77
1
/
4
76
1
1
/
4
4 FLG
3 NPT
1
1
/
2
NPT 10
12
36
24
79
5
/
8
(114.1) (97.79) (196.21) (193.0)
(3.2)
(10.16)
(7.62)
(3.81)
(25.4)
(30.5)
(91.4)
(60.9)
(202.24)
AB-120
54
3
/
16
38
1
/
2
77
1
/
4
85
3
/
8
1
1
/
4
4 FLG
3 NPT
1
1
/
2
NPT 10
12
36
24
79
5
/
8
(137.6) (97.79) (196.21) (216.8)
(3.2)
(10.16)
(7.62)
(3.81)
(25.4)
(30.5)
(91.4)
(60.9)
(202.24)
AB-150
63
1
/
2
38
1
/
2
77
1
/
4
94
3
/
4
1
1
/
2
6 FLG
3 NPT
1
1
/
2
NPT 10
12
36
24
79
5
/
8
(161.3) (97.79) (196.21) (260.7)
(3.8)
(15.24)
(7.62)
(3.81)
(25.4)
(30.5)
(91.4)
(60.9)
(202.24)
AB-200
78
15
/
16
38
1
/
2
77
1
/
4
110
2
6 FLG
3 NPT
1
1
/
2
NPT 10
16
1
/
2
36
24
79
5
/
8
(200.5) (97.79) (196.21) (279.4)
(5.1)
(15.24)
(7.62)
(3.81)
(25.4)
(41.9)
(91.4)
(60.9)
(202.24)
AB-250
94
7
/
16
38
1
/
2
77
1
/
4
125
1
/
2
2
6 FLG
3 NPT
1
1
/
2
NPT 12
15
36
24
79
5
/
8
(239.9) (97.79) (196.21) (318.8)
(5.1)
(15.24)
(7.62)
(3.81)
(30.5)
(38.1)
(91.4)
(60.9)
(202.24)
AB-300
108
13
/
16
38
1
/
2
77
1
/
4
140
15
/
16
2
6 FLG
3 NPT
1
1
/
2
NPT 12
15
36
24
79
5
/
8
(276.4) (97.79) (196.21) (358.0)
(5.1)
(15.24)
(7.62)
(3.81)
(30.5)
(38.1)
(91.4)
(60.9)
(202.24)
WATER BOILER DIMENSIONS — inches (cm)
A B C D
E
F
G H I
J
K
L
Boiler Length
Width
Height
Gas
Train
Clearance for
Min. Tube Floor to
Model
of Outside Over
Overall
Connection
Supply Return
Flue Flue
Servicing Removal
Flow
Number Jacket Jacket Jacket
Length
(Approx.)
Nozzle Nozzle
Size
Location
Burner Clearance
Nozzle
AB-90
44
15
/
16
34
3
/
4
69
1
/
2
76
1
1
/
4
3-F 3-F
10
12
36
24
74
7
/
8
(114.1) (88.3) (176.5) (193.0)
(3.2)
(7.6)
(7.6) (25.4) (30.5)
(91.4)
(60.9) (190.2)
AB-120
54
3
/
16
34
3
/
4
69
1
/
2
85
3
/
8
1
1
/
4
3-F 3-F
10
12
36
24
74
7
/
8
(137.6) (88.3) (176.5) (216.8)
(3.2)
(7.6)
(7.6) (25.4) (30.5)
(91.4)
(60.9) (190.2)
AB-150
63
1
/
2
34
3
/
4
69
1
/
2
94
3
/
4
1
1
/
2
3-F 3-F
10
12
36
24
74
7
/
8
(161.3) (88.3) (176.5) (260.7)
(3.8)
(7.6)
(7.6) (25.4) (30.5)
(91.4)
(60.9) (190.2)
AB-200
78
15
/
16
34
3
/
4
69
1
/
2
110
2
3-F 3-F 10 16
1
/
2
36
24
74
7
/
8
(200.5) (88.3) (176.5) (279.4)
(5.1)
(7.6)
(7.6) (25.4) (41.9)
(91.4)
(60.9) (190.2)
AB-250
94
7
/
16
34
3
/
4
69
1
/
2
125
1
/
2
2 3-F 3-F
12
15
36
24
74
7
/
8
(239.9) (88.3) (176.5) (318.8)
(5.1)
(7.6)
(7.6) (30.5) (38.1)
(91.4)
(60.9) (190.2)
AB-300
108
13
/
16
34
3
/
4
69
1
/
2
140
15
/
16
2 3-F 3-F
12 15
36
24 74
7
/
8
(276.4) (88.31) (176.5) (353.0)
(5.1)
(7.6)
(7.6) (30.5) (38.1)
(91.4)
(60.9) (190.2)