beautypg.com

Bakers Pride SGBR User Manual

Page 7

background image

8.

Each burner may now be adjusted to the desired flame size by turning the individual burner

valve handle.

9.

To shut down the unit, turn all valves "OFF".

THE PILOT BURNERS WILL STAY LIT UNTIL THE MAIN GAS SUPPLY TO THE

UNIT IS TURNED "OFF".

AFTER TURNING BROILER CONTROL VALVES OFF, ALWAYS WAITAT LEAST 5

MINUTES BEFOREATTEMPTING TO RELIGHT IF PILOT BURNER GOES OUT.

a.

Keep the area around the broiler free and clear of combustible materials.

b.

The provisions of an adequate air supply to your broiler is essential. Provide for

sufficient air to enter the broiling area and assure that this air flow is not obstructed.

c.

Air enters the burner area from the front and bottom of your broiler.Assure that

these areas are kept open and unobstructed.

.

d.

Servicing is accomplished through the front and top of the broiler.Assure. that

these areas are kept unobstructed for proper servicing and operation.

a.

Install the casters with wheel brakes on the front of the appliance.

b.

Installation should be made with a connector that complies with the latest edition

of the Standard connectors for Movable Gas Appliances ANSI Z21.69 in USA (CAN CGA-

6.16 in Canada) and a quick disconnect Device that complies with the latest edition of the

Standard for Quick Disconnect Devices for use with gas fuel ANSI Z21.41 in USA (CAN 1-

6.7 in Canada) and adequate means must be provided to limit the movement of the

appliance without depending on the connector and any quick disconnect device or its

associated piping to limit the appliance movement.

c.

The restraint should be attached to one of the legs on which the casters are mounted.

d.

If disconnection of the restraint is necessary, the restraint should be reconnected after the

appliance has been returned to its originally installed position.

NOTE:

CAUTION:

7. ADDITIONAL INSTALLATION REQUIREMENTS:

8. INSTALLATION WITH CASTERS:

7