beautypg.com

Appendix e, Eprom upgrade – Bay Technical Associates DS4-RPC User Manual

Page 96

background image

DS-RPC OWNER’S MANUAL
APPENDIX E
__________________________________________________________________________________________

89

APPENDIX E

EPROM UPGRADE

If you receive an EPROM upgrade, you will need a screwdriver and an IC
DIP extractor or a pair of curved needle-nose pliers

1. Remove all power from the unit by placing the power switch to the 0

position and disconnecting the power supply from the outlet.

2. Remove the appropriate module by loosening the 2 straight slotted

screws that attach the module to the chassis, then pull the module out.

3. Refer to Appendix D (DS71 or DS71-MD2 module Mechanical

Layouts); locate socket U2.

4. Remove existing EPROM from socket U2 with IC extractor or

needle-nose pliers. Gradually loosen each side of the chip, alternating
pliers from side to side being careful not to bend chip pins.

5. Install the EPROM into socket U2. The EPROM is notched; the notch on

the EPROM should line up with the notch on the socket. Seat each pin
securely in its socket being careful not to bend chip pins.

6. By moving a hardware jumper, reset the DS71 or DS71-MD2 module to

default configuration status.

a. Refer to Appendix D (DS71 or DS71-MD2 module Mechanical

Layouts), locate Jumper JP4.

b. Jumper JP4 connects the two pins that are closest to the aluminum

face plate on the module. These pins are labled “RUN”.

c. Connect the two pins that are further from the face plate of the

module by moving Jumper JP4. These pins are labled “TEST”.

This manual is related to the following products: