ELECTRICAL REQUIREMENTS

The grinder has an attached cordset and requires 2-wire, grounded service rated 230 volts ac, 10 amp single

phase, 50 Hz for 230V models.

P1028

P1029

OPERATING CONTROLS

Off/On/Start Switch (Models LPGA and LPGA-2E)

OFF - (upper position) Switching to this position stops all operation of

the grinder.

ON - (middle position) The switch will return to this position after a grind

cycle has begun and will remain in this position after grinding has ceased.

START - (lower, momentary position) Pressing the switch to this position

and releasing initiates a grind cycle.

Hopper Selector Switch (Model LPGA-2E only)

LEFT - Switching to this position allows beans to be ground from the left

hopper.

RIGHT - Switching to this position allows beans to be ground from the

right hopper.

27091.1 042211

CE REQUIREMENTS

• This appliance must be installed in locations where it can be overseen by trained personnel.

• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

• Appliance shall not be tilted more than 10° for safe operation.

• An electrician must provide electrical service as specified in conformance with all local and national codes.

• This appliance must not be cleaned by water jet.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental

capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of

this appliance by a person responsible for its safety.

• Children should be supervised to ensure they do not play with the appliance.

• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with

a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

• Machine must not be immersed for cleaning.

• Machine rated IPX1.

PREVENTIVE MAINTENANCE

Bunn-O-Matic

®

Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance

should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic

®

Corporation at

1-800-286-6070.
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.

6-Month

Weekly Cleaning plus replace the dechaffer assembly.

1-Year

1. On grinders with slide plates check the slide plates and clean.

2. Inspect and clean/replace burrs and grind chamber if necessary.

3. Adjust the burrs and grind time to your specifications for particulate size and throw weight.