LEGEND
W2
— Second-Stage Heat
Y2
— Second-Stage Compressor
RS2
— Second Remote Sensor (Not Used)
RS+5
— +5 vdc for 2 Sensors
RS1
— Remote Sensor
RS GND — Ground for 2 Sensors
W1/O/B
— First-Stage Heat or Reversing Valve
Y1
— First-Stage Compressor
G
— Fan
W3/ECO — Third-Stage Heat or Economizer (Not Used)
CK1
— Dry Contact
CK2
— Dry Contact Ground
R
— 24 vac Transformer
C
— 24 vac Transformer Common
Fig. 2 — Thermostat Wiring
W2
TYPICAL
UNIT
L
C
G
Y1
E
O
W1
R
Y2
24 VAC COMMON
FAN RELAY
COMPRESSOR RELAY
1st STAGE HEAT CIRCUIT
24 VAC RETURN
2nd STAGE HEAT CIRCUIT
W2 Y2 R W1 Y1 G
C
THERMOSTAT
B
O
Fig. 3 — Typical Wiring (Single-Stage Cooling Units)
W2
TYPICAL
UNIT
L
C
G
Y1
E
O
W1
R
Y2
24 VAC COMMON
FAN RELAY
COMPRESSOR RELAY
1st STAGE HEAT CIRCUIT
24 VAC RETURN
2nd STAGE COMPRESSOR RELAY
2nd STAGE HEAT CIRCUIT
W2 Y2 R W1 Y1 G
C
THERMOSTAT
B
O
Fig. 4 — Typical Wiring (Two-Stage Cooling Units)
Table 1 — Thermostat Wiring Terminations
EXISTING
WIRE
DESIGNATION
FUNCTION
TERMINAL
CONNECTION
G or F
Fan
G
Y1, Y, or C
Cooling
Y1
W1, W, or H
Heating
W1/O/B
Rh, R, M, Vr, or A
Power (24 v)
R
C
Common
C*
O/B
Reversing Valve
W1/O/B†
Y2
Second Stage Cooling
Y2*
W2
Second Stage Heating
W2*
RS+5
Remote Sensor (5 vdc)
RS+5
RS
Remote Sensor Signal
RS1
RS G
Remote Sensor Ground
RS GND
CK1
Dry Contact Switch
CK1
CK2
Dry Contact Ground
CK2
*Terminals C, Y2, and W2 may not be used in all applications.
†Used on Heat Pump applications only.
—3—