Read and save these instructions, Warning, Caution – Best EB6 User Manual

Page 2: Specifications, Plan the installation

background image

2

READ AND SAVE THESE INSTRUCTIONS

WARNING

5. When cutting or drilling into wall, or ceil-

ing, do not damage electrical wiring or

other hidden utilities.

6. Ducted fans must always be vented to

the outdoors.

7. To reduce risk of fire, use only metal

ductwork.

8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not

use to exhaust hazardous or explosive

material and vapors.

2. To avoid motor bearing damage and

noisy and/or unbalanced impellers, keep

drywall spray, construction dust, etc. off

power unit.

3. Please read specification label on prod-

uct for further information and require-

ments.

4. Electrical circuit, including speed con-

trol, (if used), must be rated 6 AMPS

minimum for Model EB9 or 3 AMPS

minimum for Model EB6.

WARNING

TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended

by the manufacturer. If you have ques-

tions, contact the manufacturer at the

address or telephone number listed in

the warranty.

2. Before servicing or cleaning unit, switch

power off at service panel and lock the

service disconnecting means to prevent

power from being switched on acciden-

tally. When the service disconnecting

means cannot be locked, securely fasten

a prominent warning device, such as a

tag, to the service panel.

3. Installation work and electrical wiring must

be done by a qualified person(s) in accor-

dance with all applicable codes and stan-

dards, including fire-rated construction

codes and standards.

4. Sufficient air is needed for proper com-

bustion and exhausting of gases through

the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the

heating equipment manufacturer's guide-

line and safety standards such as those

published by the National Fire Protection

Association (NFPA), and the American

Society for Heating, Refrigeration and

Air Conditioning Engineers (ASHRAE),

INSTALLER: Leave This Manual With The Homeowner.

HOMEOWNER: Use And Care Information On Page 4.

SPECIFICATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

EB6

120

2.4

600

10 " DIA.

EB9

120

5.7

900

10" DIA.

PLAN THE INSTALLATION

1. Locate the blower so the length of the

duct run and number of elbows are kept

to a minimum.

2. Where possible, blower should be cen-

tered between wall studs or roof rafters.

ALL INSTALLATIONS

PLAN THE INSTALLATION

3. Avoid pipes, wires, or other ductwork that

may be running through the wall.

4. Attach mounting plate to top of hood.
5. Install 10” dia. ductwork and 120 VAC

house wiring between blower location

and hood location.