INDICATOR LIGHTS

Mains electricity indicator:

OFF : No mains electricity to the appliance

ON : Mains electricity is connected to the

appliance

Central heating demand indicator:

OFF : No demand for heat to the central

heating circuit

ON : Central heating demand

FLASHING SLOW : Ignition lockout

(once per second)

FLASHING FAST : Appliance fault (other than ignition

(five times per second)

lockout)

Domestic hot water demand indicator:

OFF : No demand for domestic hot water

ON : Domestic hot water demand

FLASHING FAST : Air flow fault (RSF). Flue gas spillage

(OF)

(five times per second)

Central heating and domestic hot water demand indicators:

BOTH FLASHING SLOW : Overheat cut-off

(once per second)

Flame detection indicator:

OFF : Burner off

ON : Burner on

Fig. 2. Controls.

Operating

switch

Mains
electricity
indicator

Reset

button

Flame detection

indicator

DHW demand

indicator

Central heating

demand indicator

CH temperature

control knob

DHW temperature

control knob

Sealed system pressure

gauge