beautypg.com

Specifications – Bogen M600 User Manual

Page 19

background image

Specifications

15

* Both channels driven at nominal line voltage 120V AC, 60 Hz.
** Requires 20A, NEMA 5-20R Type Receptacle.

Technical Specifications

M600

M450

M300

Power Output

70V Mono
4-ohm
8-ohm

1200W @ 4 ohms

600W per channel*
400W per channel*

900W @ 5.5 ohms

450W per channel*
300W per channel*

600W @ 8 ohms

300W per channel*
200W per channel*

Input Sensitivity

At Backplane Connector or using
Standard Input Module (incl.)

(Module has Gain of

1)

1.161V for 600W @ 4 ohms

1.010V for 450W @ 4 ohms

0.840V for 300W @ 4 ohms

S/N Ratio (20K BW)

109 dB ref. 8 ohms, F.P.

106 dB ref. 8 ohms, F.P.

103 dB ref. 8 ohms, F.P.

Class of Operation

H

H

AB

Product Weight

46 lb.

44 lb.

41 lb.

Connectors: Power

Input

Output

20A line cord**

15A line cord

15A line cord

Dependent on modules installed (stereo, high-impedance balanced input module w/screw terminals included) /RCA (Mono/70V mode, unbalanced)

5-pin "touch-proof" Barrier Strip, RCA Pre- & Post-EQ Output

Power Bandwidth

20 Hz to 40 kHz .5% THD

THD @ 1 kHz rated power

less than .02%

Load Impedance

4-8 ohms, 70V

Minimum Load Impedance (Stereo)

3.2 ohms

Frequency Response @ 1 watt

20 Hz to 20 kHz +/- 0.25 dB

Output Regulation,

1 kHz direct
1 kHz bridged

0.5 dB @ 8 ohms

1.5 dB @ 70V

Inputs (Plug-in modules)

Electronically balanced, high-impedance module standard, other modular input types available

AC Input Voltage Range

95 to 130VAC, 60 Hz

Maximum AC Current

20A**

15A

12A

Indicators

Status (On/Protect/Sleep), Clip/Limit, Signal

Cooling

Forced Air Variable Speed Fan

Physical Dimensions (W x H x D)

17" X 3-1/2" x 18-1/2" (not including brackets)

Protection

RF, DC, Low-frequency, Thermal, Low-Impedance, Circuit-Breaker, Short Circuit

Special Features

Sleep Mode, Back-Slope regulation, Stereo, Dual Mono, 70V Mono Operation, Toroidal Power Transformer

Approvals

Thermal Emissions 1913 BTU/hr. 1537 BTU/hr. 1195 BTU/hr.

Listed to UL Standard 60065 for U.S. and Canada