WATER BOILER DIMENSIONS in inches (cm)

A

B

C

D

E

F

G

H

I

J

K

L

Boiler

Overall

Floor to

Width

Length

Height

Gas Train

Supply

Return

Flue

Flue

Min. Tube

Clearance for

Model

Length

Flow

Outside

of

Over

Connection

Nozzle

Nozzle

Size

Location

Removal

Servicing

Number

Nozzle

Jacket

Jacket

Jacket

Clearance

Burner

DR350-W

62

1

/

8

67

7

/

8

32

1

/

8

32

3

/

8

66

3

/

8

1

2

2

6

12

13

/

16

24

30

(157.80)

(172.40)

(81.60)

(82.23)

(168.59)

(2.54)

(5.08)

(5.08)

(15.24)

(32.54)

(60.96)

(76.20)

DR450-W

62

1

/

8

67

7

/

8

32

1

/

8

32

3

/

8

66

3

/

8

1

2

2

6

12

13

/

16

24

30

(157.80)

(172.40)

(81.60)

(82.23)

(168.59)

(2.54)

(5.08)

(5.08)

(15.24)

(32.54)

(60.96)

(76.20)

DR650-W

73

1

/

2

67

7

/

8

32

1

/

8

43

3

/

4

66

3

/

8

1

2

2

8

12

13

/

16

24

30

(186.69)

(172.40)

(81.60)

(111.13)

(168.59)

(2.54)

(5.08)

(5.08)

(20.32)

(32.54)

(60.96)

(76.20)

DR850-W

73

1

/

2

67

7

/

8

32

1

/

8

43

3

/

4

66

3

/

8

1

2

2

8

12

13

/

16

24

30

(186.69)

(172.40)

(81.60)

(111.13)

(168.59)

(2.54)

(5.08)

(5.08)

(20.32)

(32.54)

(60.96)

(76.20)

PLAN VIEW

FRONT VIEW

LEFT SIDE VIEW

REAR VIEW

Bryan DR Series Steam & Hot Water Boilers

Specifications subject to change without notice. Consult factory to consult on other boiler options.

Form No. 3710 ©2004 Bryan Steam LLC

Printed in USA

64-6166

Bryan Steam LLC — Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet: www.bryanboilers.com
Fax: 765-473-3074 • E-mail: [email protected]

STEAM BOILER DIMENSIONS in inches (cm)

A

B

C

D

E

F

G

H

I

J

K

L

Boiler

Overall

Floor to

Width

Length

Height

Gas Train Supply Nozzle

Return

Flue

Flue

Min. Tube

Clearance

Model

Length

Flow

Outside

of

Over

Connection

Conn.

Size

Location

Removal

for Servicing

Number

Nozzle

Jacket

Jacket

Jacket

(Approx.)

15 psi

150 psi

Clearance

Burner

DR250-S*

62

1

/

8

74

5

/

8

33

13

/

16

32

3

/

8

71

3

/

4

1

NA**

3

2

6

12

13

/

16

24

30

(157.80)

(189.54)

(85.88)

(82.23)

(182.25)

(2.54)

(7.62)

(5.08)

(15.24)

(32.54)

(60.96)

(76.20)

DR350-S

62

1

/

8

74

5

/

8

33

13

/

16

32

3

/

8

71

3

/

4

1

3

3

2

6

12

13

/

16

24

30

(157.80)

(189.54)

(85.88)

(82.23)

(182.25)

(2.54)

(7.62)

(7.62)

(5.08)

(15.24)

(32.54)

(60.96)

(76.20)

DR450-S

62

1

/

8

74

5

/

8

33

13

/

16

32

3

/

8

71

3

/

4

1

3

3

2

6

12

13

/

16

24

30

(157.80)

(189.54)

(85.88)

(82.23)

(182.25)

(2.54)

(7.62)

(7.62)

(5.08)

(15.24)

(32.54)

(60.96)

(76.20)

DR650-S

73

1

/

2

74

5

/

8

33

13

/

16

43

3

/

4

71

3

/

4

1

4

4

2

8

12

13

/

16

24

30

(186.69)

(189.54)

(85.88)

(111.13) (182.25)

(2.54)

(10.16)

(10.16)

(5.08)

(20.32)

(32.54)

(60.96)

(76.20)

DR850-S

73

1

/

2

74

5

/

8

33

13

/

16

43

3

/

4

71

3

/

4

1

4

4

2

8

12

13

/

16

24

30

(186.69)

(189.54)

(85.88)

(111.13) (182.25)

(2.54)

(10.16)

(10.16)

(5.08)

(20.32)

(32.54)

(60.96)

(76.20)

PLAN VIEW

FRONT VIEW

LEFT SIDE VIEW

REAR VIEW

NOTE: Dimensions subject to change without notice. Consult factory for certified dimensions.

* Not intended for use as a principal heating source for the living space of an individual residence.
** Not available in 15 psi construction.

This manual is related to the following products: