Technical data, Closing the door – AEG AGS58200F0 User Manual
Page 13
Problem
Possible cause
Solution
The FROSTMATIC function is
switched on.
Refer to "FROSTMATIC function".
The temperature in the
freezer is too low.
The temperature regulator is
not set correctly.
Set a higher temperature.
The FROSTMATIC function is
switched on.
Refer to "FROSTMATIC function".
The temperature in the
freezer is too high.
The temperature regulator is
not set correctly.
Set a lower temperature.
The door is not closed correctly. Refer to "Closing the door".
The product temperature is too
high.
Let the product temperature de-
crease to room temperature be-
fore storage.
Many products are stored at
the same time.
Store less products at the same
time.
Products are too near to each
other.
Store products so that there is
cold air circulation.
There is too much frost.
Food is not wrapped correctly.
Wrap the food correctly.
The door is not closed correctly. Refer to "Closing the door".
The temperature regulator is
not set correctly.
Set a higher temperature.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Center.
TECHNICAL DATA
Dimension of the recess
Height
880 mm
Width
560 mm
Depth
550 mm
Rising Time
20 h
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
Technical data
13