DIAGNOSTICS

Intermittent flashing of the READY indicator (Model CEZ) or the bank of temperature indicators (Model CDBC)
indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to
investigating the fault.

FLASHES CAUSE

THINGS TO CHECK

1

Dry Plug - In Fault -

Water Pressure

Sheath of temperature probe dry for 10 minutes after power-up

Temperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board

2

Low Tank Level Fault -

Water pressure

Level probe dry for 7 minutes after fill valve is energized

Level probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer

3

Low Water Temperature Fault -

Tank heater wiring & function

Sensor in tank is calling for heat for 30 minutes or more

Temperature probe wiring

4

Tank Sensor Disagreement -

Temperature probe wiring

Level probe detects water, but dry plug-in probe dry

Level probe wiring
Green wire between tank and circuit board

5

Temp Sensor Out-of-Range - High

Sensor not connected to circuit board

6

Temp Sensor Out-of-Range - Low

Sensor wires shorted together or to chassis