Assembly – AEG HK634060XB User Manual

Page 6

background image

• A qualified electrician must install the clamping connections correctly.
• Use a strain relief clamp on cable.
• Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single-phase.
• Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or

higher). Speak your local Service Force Centre.

The appliance must have the electrical installation which lets you disconnect the appliance

from the mains at all poles with a contact opening width of minimum 3 mm.

You must have correct isolation devices: line protecting cut-outs, fuses (screw type fuses

removed from the holder), earth leakage trips and contactors.

If, you use the accessory frame C-FRAME, first read the instruction supplied with the frame

before you install the appliance.

Assembly

min.
50mm

min.
50mm

min.
500mm

=

=

340

+1

mm

600mm

490

+1

mm

R 5mm

min.

25 mm

min.

20 mm

6

Installation instructions