A.O. Smith GW/GWO-1000 User Manual

Page 2

background image

A 012.16

ALTERNATE EXHAUST

AIR INLET

G

ELECTRICAL

CONNECTIONS

OUTLET/ECO

F

31 3/4"

FLOW

SWITCH

A

C

17"

D

TOP VIEW

INLET
TEMP.

E

GAS INLET

5 7/16"

CONTROL BOX CONTAINING

CCB AND ICB BOARDS

PRESSURE RELIEF VALVE

B

14 1/2"

HOT WATER SUPPLY BOILER RECOVERY CAPACITIES

Temperature Rise -Degrees F. Gallons Per Hour

Input Rating BTU/Hr.

Natural &

Model

Propane (LP) Gas

40

50

60

70

60

90

100

110

120

130

GW-1000

990,000

GPH

2520

2016

1680

1440

1260

1120

1008

918

840

775

GW-1300

1,300,000

GPH

3309

2847

2208

1891

1655

1471

1324

1203

1103

1018

GW-1500

1,500,000

GPH

3818

3055

2545

2182

1909

1697

1527

1388

1273

1175

GW-1850

1,850,000

GPH

4709

3767

3139

2691

2355

2093

1884

1712

1570

1449

GW-2100

2,100,000

GPH

5345

4276

3564

3055

2673

2376

2138

1944

1782

1645

GW-2500

2,490,000

GPH

6338

5071

4225

3622

3169

2817

2535

2305

2113

1950

Genesis BTU Input/Output And Flow Rates

BTU Input/Output

Boiler Rate of Flow and Pressure Drop

Input Rating BTU/Hr. Output Rating BTU/Hr. 20 Deg. F Rise 30 Deg. F Rise 40 Deg. F Rise

Maximum Flow Rate Minimum Flow Rate

Natural &

Natural &

PD-Ft.

PD-Ft.

PD-Ft.

PD-Ft.

Deg.F

PD-Ft. Deg.F

Model

Propane (LP) Gas

Propane (LP) Gas

GPM

Head

GPM

Head

GPM

Head

GPM Head

Rise

GPM Head

Rise

GW-1000

990,000

831,600

83

5.1

55

2.7

42

1.5

154

12.2

11

42

1.5

40

GW-1300

1,300,000

1,092,000

109

72

73

4.2

55

3.2

154

14.5

14

55

3.2

40

GW-1500

1,500,000

1,260,000

126

10.1

84

8.3

83

4.3

154

16.3

17

64

4.3

40

GW-1850

1,650,000

1,554,000

154

19

104

10.1

78

6.4

154

16.5

20

78

6.4

40

GW-2100

2,100,000

1,764,000

N/A

N/A

116

14.5

68

8.3

154

21.3

23

89

8.3

40

GW-2500

2,490,000

2,091,600

N/A

N/A

139

16.5

105

11.6

154

23.2

26

106

11.6

40

Note: Flow rates and pressure drops shown above are through the boiler only and include no field piping. The field piping must also be

considered when sizing system pumps.

Note: The standard factory supplied internal rear header mounted pump is sized for the boiler and up to additional 50 equivalent feet

of field piping.

All Dimensions in Inches

A

Water

Gas

Width

B

Width

Model

Connections

Connections

Vent

Inlet Air

WO/Pump

Height

C

D

E

F

G

W/Pump

GW-1000

2 1/2

2

10

8

47

40 1/2

14

12 1/2

36 1/4

31 3/4

20 3/4

64

GW-1300

2 1/2

2

12

10

57 1/2

40 1/2

24 3/4

12 1/2

36 1/4

31 3/4

16 1/2

74 1/2

GW-1500

2 1/2

2

12

10

64 1/2

40 1/2

30

12 1/2

36 1/4

31 3/4

18

81 1/2

GW-1850

2 1/2

2 1/2

14

12

78 3/4

43 1/4

27 3/4

11 1/2

35 1/4

32 1/2

34 1/4

95 3/4

GW-2100

2 1/2

2 1/2

14

12

85 1/2

43 1/4

31

11 1/2

35 1/4

32 1/2

33 1/2

102 1/2

GW-2500

2 1/2

2 1/2

16

14

99 1/2

43 1/4

38

11 1/2

35 1/4

32 1/2

36 1/4

116 1/2

Maximum gas supply pressure is 13.8" W.C. for both Natural and Propane Gas.
The minimum supply gas pressure is 7" W.C. for Natural Gas.
The minimum supply gas pressure for Propane is 11.0" W.C.
Requires: 120V, 60 Hz, 30 Amps.