7. TECHNICAL DATA
Dimension
Height
1850 mm
Width
595 mm
Depth
658 mm
Rising Time
18 h
Voltage
230 - 240 V
Frequency
50 Hz
The technical information are situated in
the rating plate on the internal left side
of the appliance and in the energy label.
8. INSTALLATION
WARNING!
Read the "Safety Information"
carefully for your safety and cor-
rect operation of the appliance
before installing the appliance.
8.1 Positioning
Install this appliance at a location where
the ambient temperature corresponds to
the climate class indicated on the rating
plate of the appliance:
Cli-
mate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
8.2 Location
A
B
mm
mm
min
10
0
20
The appliance should be installed well
away from sources of heat such as radia-
tors, boilers, direct sunlight etc. Ensure
that air can circulate freely around the
back of the cabinet. To ensure best per-
formance, if the appliance is positioned
below an overhanging wall unit, the min-
imum distance between the top of the
cabinet and the wall unit must be at least
100 mm . Ideally, however, the appliance
should not be positioned below over-
hanging wall units. Accurate levelling is
ensured by one or more adjustable feet
at the base of the cabinet.
ENGLISH
13