Heat input
Triple Crown burner:
3.8 kW
Semi-rapid burner:
1.9 kW
Auxiliary burner:
1.0 kW
TOTAL POWER:
G20 (2H) 20 mbar = 10.5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply:
230 V ~ 50 Hz
3 core flexible cable with non rewireable plug fitted
with a 3 amp cartridge fuse
Category:
II2H3+
Gas connection:
R 1/2"
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in
1/100 mm
Auxiliary
28
Burner
Ø By-pass in
1/100 mm
Semi-rapid
32
Triple Crown
56
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
inj. 1/100 mm
Auxiliary
1.0
70
Semi-rapid
1.9
96
Triple Crown
3.8
146
Gas burners for LPG (Butane / Propane) G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
inj. 1/100
mm
G30
28-30
mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
50
73
71
Semi-rapid
1.9
71
138
136
Triple Crown
3.8
98
276
271
10. ENVIRONMENT CONCERNS
Recycle the materials with the
symbol . Put the packaging in
applicable containers to recycle it.
Help protect the environment and
human health and to recycle waste
of electrical and electronic
appliances. Do not dispose
16 www.aeg.com