Rigid connection, Injectors replacement, Adjustment of minimum level – AEG HG795540XB User Manual
Page 14: Electrical connection

Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.
steel or copper.
The connection should be suitable for
connecting to R 1/2 (1/2 BSP male
thread).
When the final connection has been
made, it is essential that a thorough leak
test is carried out on the hob and installa-
tion.
Make sure that the main connection pipe
does not exert any strain on the hob.
If you use flexible metal pipes make sure
that they agree to ISO 10380 and ISO
10807 standards. Be careful they do not
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
It is important to install the elbow
correctly, with the shoulder on the
end of the thread, fitted to the
hob connecting pipe.
Failure to ensure the correct as-
sembly will cause leakage of gas.
Make sure that the gas supply
pressure of the appliance obeys
the recommended values.
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end).
INJECTORS REPLACEMENT
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Techni-
cal Data" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied
with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure adjust-
er on the gas supply pipe.
ADJUSTMENT OF MINIMUM
LEVEL
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
1
1
The by-pass screw
– If you change from natural gas G20
20 mbar to liquid gas, fully tighten
the adjustment screw in.
– If you change from liquid gas to
natural gas G20 20 mbar, undo the
by-pass screw approximately 1/4 of
a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
ELECTRICAL CONNECTION
• The electrical work necessary to install
the appliance must be done by a quali-
fied electrician or competent person,
according to the current regulations.
• The appliance must be earthed.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is access to the
mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple socket. There is a risk of fire.
Make sure that the ground connection
14 www.aeg.com