background image

5. Make sure that there are no residues

of food or soil in or around the edge

of the sump.

6. Put back in place the flat filter (A).

Make sure that it is correctly

positioned under the 2 guides.

7. Reassemble the filters (B) and (C).

8. Put back the filter (B) in the flat filter

(A). Turn it clockwise until it locks.

CAUTION!

An incorrect position of the

filters can cause bad

washing results and damage

to the appliance.

11.2 Cleaning the spray arms

Do not remove the spray arms. If the

holes in the spray arms are clogged,

remove remaining parts of soil with a thin

pointed object.

11.3 External cleaning

• Clean the appliance with a moist soft

cloth.

• Only use neutral detergents.

• Do not use abrasive products,

abrasive cleaning pads or solvents.

11.4 Internal cleaning

• Carefully clean the appliance,

including the rubber gasket of the

door, with a soft moist cloth.

• If you regularly use short duration

programmes, these can leave

deposits of grease and limescale

inside the appliance. To prevent this,

we recommend to run long duration

programmes at least 2 times per

month.

12. TROUBLESHOOTING

If the appliance does not start or it stops

during operation. Before you contact an

Authorised Service Centre, check if you

can solve the problem by yourself with

the help of the information in the table.

www.aeg.com

18